× All the transactions performed on 2.0 is available here. To access Market click "Home".

online 3kva ups with 30 min back up (eaton)(9145 -3000in-xl with 30 min back up)

` 38,700.00

  • MRP: `43000.00

INPUT -110 VAC -300va, OUTPUT - 220 ,230 ,240 VAC , BACKUP TIME - 30 Min,60, Min ,90 Min 120 Mins, INBUILT ISOLATION TRANSFORMER NA, 130 percentage OVERLOAD LIMIT FOR MINIMUM 1 MINUTES -Yes, 110 percentage OVERLOAD LIMIT FOR MINIMUM 10 MINUTES yes, TOTAL HARMONIC DISTORTION THD in percentage 3 to 5 percentage, OVERALL EFFICIENCY 92 percentage, TYPE OF BATTERY - SMF VRL, MINIMUM THICKNESS OF M.S.SHEET ENCLOSURE DULY PAINTED -1.6 MM, DEGREE OF PROTECTION - ip20, PROTECTION OF OVER VOLTAGE,SHORT CIRCUIT OVER LOAD AT UPS OUTPUT TERMINAL Yes, PROTECTION FOR UNDER VOLTAGE AT BATTERY TERMINAL AT 10.5V PER 12 V BATTERY yes, MAXIMUM OVERSHOOT AND UNDER SHOOT OF OUTPUT RATED VOLTAGE -110 to 300 percentage, INDICATORS FOR MAINS PRESENCE,BATTERY CHARGING AND DISCHARGING,OUTPUT OVER LOAD, LOW BATTERY VOLTAGE - LCD Display, DIGITAL METERING IN UPS FOR AC INPUT VOLTAGE,OUTPUT AC VOLTAGE,CURRENT,FREQUENCY,BATTERY VOLTAGE AND CURRENT - LCD Display, MOVABLE TROLLY FOR BATTERIES - yes..

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 2496 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 3 KVA
Technology MOSFET-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 2496 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 to 5 %
Overall Efficiency 92 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. R 67000361
Type Test Certificate Date 19.01.2016
Name Of Lab Bureau of Indian Standards
Address Of Lab Manak Bhavan, 9 Bahadur Shah Jafar Marg, New Delhi - 110002.
Supply & Commissioning Yes
Warranty 2 Years

Price Dekho Price Dekho Price List in india