Mixed Signal Oscilloscope - SMO2204X-M, 200MHz, 4 Analog and 16 Digital Channels, Serial Decoding.
Other Specifications Download Specification | |
---|---|
Type | Mixed Signal |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | Yes |
No. Of Digital Channels | 16 Number |
Record Length Per Digital Channel Simultaneously | 14Mpts/CH GS/sec |
Sampling Rate Per Digital Channel Simultaneously | 500MSa/s Mega Points |
Min. Detectable Pulse Width | 4 ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground |
Time Base Range | 1ns/div to 50s/div |
Trigger Types | Edge, Slope, Pulse, Video, Window, Interval, Dropout, Runt, Pattern and Serial trigger |
Measurements | Voltage Measurements:Vmax,Vmin,Vpp, Vamp,Vtop Vbase,Mean Vmean,stdev,Vstd,Vrms,Crms,FOV,FPRE,ROV,RPRE,Level@X, Time:Period,Freq,+Wid,-Wid,Rise Time,Fall Time,Bwid,+Dut,-Dut,Delay,Time@Level, Delay :Phase,FRR,FRF,FFR,FFF,LRR,LRF,LFR,LFF, :Statistics:Current, Mean, Min, Max, Std-Dev, Count, Math : Addition, subtraction, multiplication, division, FFT, differential, integral, square root |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution |
Display Type | Colour |
Display Size | 20.32 TFT LCD CM |
I/O Interface | USB, LAN |
Standard Accessories To Be Supplied | X1/X10 switchable Probe per channel, Manual & Software CD, Calibration Certificate , Power Cord. Logic Probe |
Operating Temperature Range | 10 - 40 Degree C |
Operating Humidity (RH) | 85 % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 1/17-18/0078 |
Test Report Date | 10.08.17 |
Name Of The Lab | ETDC |
Warranty | 1 Year |
Real Time Bandwidth | 200 MHz |
Record Length Per Analog Channel Simultaneously | 140MPts, 70Mpts/channel Mega Point |
Sample Rate Per Analog Channel Simultaneously | 2GSa/s, 1MSa/s simultaneously GS/sec |
Waveform Update Rate | 140000 Waveforms/ |
Time Base Accuracy | 25 PPM |