De-Sauty Bridge to determine Capacitance of a Capacitor. Decade resistance dials Standard capacitors Unknown capacitors are provided. A.C. supply of frequency 1KHz with variable amplitude and Galvanometer are provided.interconnection leads for connections comprehensive. Users Manual will explain required results.
Other Specifications Download Specification | |
---|---|
Description Of The Item | Spectrum analyzers 3GHz |
Frequency Range | 9 kHz to 3 GHz |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | Yes |
Frequency Counter Resolution(min.) | 1 Hz |
Frequency Span | 0Hz(zero span),1kHz to 3GHz |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | Yes |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | Yes |
Sweep Time @span >or= 1 KHz | 0.1S to 1000 s |
Sweep Time @span = 0 Hz | 100 micro S to 20 S |
Resolution Bandwidth (-3dB) | 100 Hz to 3 MHz in steps |
Video Bandwidth | 30 Hz to 1 MHz in steps |
Amplitude : Max Input Level For Protection | +30 dBm |
Amplitude : Max Input Level For Measurement | +20 dBm |
Amplitude :level Measurement Uncertainity | dB |
Average Noise Level Displayed | 300HzRBW,10Hz VBW: |
Markers | Normal and delta |
Trigger | Free run, video, External |
Display | TFT Colour display |
Interface | USB |
Measurement Features | CN ratio,AM,time domain power measurement,channel power measurement,Phase noise measurement,TOI,OBW |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | Yes |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 3 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | 10 Hz |
Return Loss For 2port Vector Network Analyzer | 0.00 to 60 dB |
VSWR For 2port Vector Network Analyzer | 1.01 to 10.00 |
Cable Loss For 2port Vector Network Analyzer | 0.00 to 30.00 dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | Yes |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | Yes |
Phase Range For 2port Vector Network Analyzer | -180 to +180 degree |
Phase Resolution For 2port Vector Network Analyzer | 0.01 deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | 60 dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | NA |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | Yes |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | Yes |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | NA |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz |
Warranty | 1 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | 652 |
Test Report Date | 25/05/2013 |
Name Of Lab | etdc |
Address Of The Lab | NA |