Handheld DMM TRMS 4.5 Digit 50,000 counts - The MM570A is a high accuracy multimeter. Full range multimeter functions with 0.02 basic DCV accuracy and up to 100kHz True RMS ACV bandwidth. Special True RMS combination ACDC function for measurements of rectified AC non-symmetrical voltage and current waveforms. 4 to 20mA, displayed as 0-100 for process current measurements. Dual Type K Temperature inputs, Capacitance, Frequency, Resistance, Continuity, Duty cycle and Diode tests with. Max/Min recording with auto ranging, Auto Power off, Relative Hold, as well as Peak function which captures transient pulses. Optional Windows compatible PC communication software and optically isolated cable. Complete with test leads, temperature probe, protective holster with stand and 9V battery..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 4.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | .05 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 100 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 to 45 degrees |
Operating Humidity (RH) | 80 % RH at 31 deg to 75% RH |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | Single 9 volts Alkaline battery |
Total Voltage Of Battery | Single 9V Alkaline Battery |
Standard Accessories Supplied With The Equipment | Test leads,Type K thermocouple probe(-30 to 300 degrees),protective holster with stand ,software and 9V battery. |
Dimensions (H X W X L) | 35.5 x 87 x 186 mm x mm x |
Weight | 390 grams without holster ,500 grams with holster gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Yes |
Test Report Date | Yes |
Name Of The Lab | Yes |
Warranty | 3 Year |