× All the transactions performed on 2.0 is available here. To access Market click "Home".

earth ground tester (fluke)(fluke 1623-2 earth ground tester)

` 289,950.00

  • MRP: `370000.00

The Fluke 1623-2 GEO Earth Ground Tester offers data storage and download capabilities via USB port. World class accessories will simplify and speed up testing time.3- and 4-pole Fall-of-Potential, earth resistance loop testing,4-pole Soil Resistivity testing,Selective earth ground rod testing using 1 clamp,Stakeless earth ground rod testing using 2 clamps,IP56 rated for outdoor use,Rugged carrying case,USB data storage and transfer, Internal memory storage up to 1500 records accessible via USB port,Display with special symbols, digit height 25 mm, Wide Measuring range- 0.020 ohm to 19.99 k ohm, Protection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1 Pollution degree 2,Automatic range selection,You can also perform earth ground tests in places youve not considered before inside bldgs, power pylons, or anywhere you dont have access to soil...

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurable Earth resistance range - Auto ranging
  • 2-pole method for resistance measurement - YES
  • 3-pole method for resistance measurement - YES
  • Number of the stakes - 04 NOS.
  • Diameter of the Stakes - 0.8 cm
Other Specifications Download Specification
Display Type 3 digit LCD display
Measurable Earth Resistance Range Auto ranging
2-pole Method For Resistance Measurement YES
3-pole Method For Resistance Measurement YES
4-pole Method For Resistance Measurement YES
Number Of The Stakes 04 NOS.
Material Of The Stakes GI Steel
Length Of The Stakes 46 cm
Diameter Of The Stakes 0.8 cm
Number Of The Test Leads 1 set of Testleads and Reel Cables of.. (1) 50 m cable reel of red wire.. (1) 25 m cable reel of blue wire.. (1) 25 m cable reel of green wire Nos.
Length Of The Test Leads Test leads- 1.5 M and Reel Cables 25 m - 2 nos and 50 m- 1 no cm
No. Of Test Leads With Clamps 02 Nos.
Length Of Test Leads With Clamps 150 cm
Measuring Range1 For Earth Resistance 0.02 Ohm to 19.99 K Ohms
Measuring Range2 For Earth Resistance 0.02 Ohm to 19.99 K Ohms
Measuring Range3 For Earth Resistance 0.02 Ohm to 19.99 K Ohms
Measuring Range4 For Earth Resistance 0.02 Ohm to 19.99 K Ohms
Measuring Range5 For Earth Resistance 0.02 Ohm to 19.99 K Ohms
Measuring Range6 For Earth Resistance NA Ohms
Measuring Range7 For Earth Resistance NA Ohms
Measurable Earth Resistance Resolution For Range1 0.001 to 10 Ohms
Measurable Earth Resistance Resolution For Range2 0.001 to 10 Ohms
Measurable Earth Resistance Resolution For Range3 0.001 to 10 Ohms
Measurable Earth Resistance Resolution For Range4 0.001 to 10 Ohms
Measurable Earth Resistance Resolution For Range5 0.001 to 10 Ohms
Measurable Earth Resistance Resolution For Range6 NA Ohms
Measurable Earth Resistance Resolution For Range7 NA Ohms
Measurable Earth Resistance Accuracy For Range1 (2 rdg + 3 d) reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range2 (2 rdg + 3 d) reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range3 (7 rdg + 3 d) reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range4 (7 rdg + 3 d) reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range5 (7 rdg + 3 d) reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range6 NA ±% reading ± digits
Measurable Earth Resistance Accuracy For Range7 NA ±% reading ± digits
Stakeless Test(Clamp On) yes
Facility To Measure Earth Voltage Not Available
If Yes,Measurable Earth Voltage Range NA Volts
If Yes,Measurable Earth Voltage Accuracy NA %
Minimum Open Circuit Output Voltage 48 Volts
Low Battery Indication Available
Over Range Indication Available
If Yes,Measurable Earth Voltage Resolution NA Volts
Internal Memory 1500
Type Of Battery Used In The Power Supply AA
Battery Backup Time >3000 measurements, typical, RH + RE 6000 measurements, typical, RH + RE > 10 kOhm Hours
Battery Charger Provided With The Meter. NA
Weight Of The Tester 1100 grams
Dimensions(LXWXH) 25X13.3X18.7 cmXcmXcm
Provision For External SD Card No
Interface YES, USB
Operating Temperature Range -10 C to 50 C degree celsius
Operating Humidity Range 5-95 %
All Connecting Cables And Accessories To Be Supplied Along With The Tester. Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. GEO Earth Ground Tester Users Manual Batteries Quick Reference Guide USB Cable 2 Clamps C1620 Professional Carrying Case 4 Earth Ground Stakes 3 Cable Reels
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. Yes
Type Test Report No. 3945666
TTC Report Date 10 Oct 17
Name Of Lab Fluke
Address Of Lab USA

Price Dekho Price Dekho Price List in india