The unit comprises of steam jacket electrically heated inner lid made of stainless steel work on 3-phase 440A/C 50HZ supply fitted with automatic pressure control switch safety valve etc Chamber:- The chamber is made of 16SWG304 SS. Pressure gauge, water outlet valve and air inlet valve, SS steam condenser, tube with SS eject valve. Steam Generator: - The steam generator is made out of SS heavy gauge fitted with pressure gauge and water draining valve. Outer cover:- The outer cover is made out of SS duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. Principle:- The steam generates from the jacket and gets condensed by the help of the eject valve which goes through condensing tube the dry steam gets into the chamber to penetrate into the packs contained in the chamber. Our dry vertical autoclaves are triple walled units. Outer body of our autoclave is constructed out of thick gauge stainless steel sheet of SS-304 grade. The inner chamber is also made of heavy gauge stainless steel sheet of SS-304 grade. The middle wall is also constructed from the strong and sturdy stainless steel sheet of ss-304 grade s stainless steel sheet. These are steam stocking models connected with a three way valve to control the sterilization cycle inside the autoclave. Our autoclaves are air insulated from inside, however we may incorporate mineral glass wool insulation if the customer desires so. The strong lid constructed out of thick stainless steel plate has a double safety radial locking arrangement, which ensures an easy and smooth opening and closing operation for all our autoclaves. Our deluxe vertical autoclaves are ideally suited for Bio-Tech laboratories, hospitals and research labs where safety is the first priority of the users, since it is equipped with a double safety steam release valve. At the same time we test all our autoclaves for up to 2.5 times the standard working pressure to ensure maximum safety and protection from any unfortunate incident. All our triple walled vertical autoclaves are supplied complete with pressure gauge, pressure release valve and stainless steel basket as a standard feature. HEATING: The heating process in our triple walled vertical autoclave is done through specially designed water heaters of suitable wattage to ensure optimum sterilization time in every sterilization cycle. Provided with ISI marked electric heaters. Pressure is controlled by pressure stat and temperature indicator is also provided. The pressure is controlled from 1.2 kg. to 2.00kg./cm2.Provided with double safety valve, Water inlet& outlet valves, pressure release valve S.S wire basket. The panel is provided with controls & indicators, 60 minute timer. WORKING TEMPERATURE: As per the international standards and guidelines our triple walled vertical autoclaves have a working temperature of 1210C. , however for specific requirements our autoclaves can be upgraded to be used for up to 1340C. WORKING PRESSURE: Working pressure for our standard dry sterilization model vertical autoclave is 15 psi, however this can be upgraded to be used for higher pressures of up to 30 psi. PRESSURE RANGE: The normal pressure range of our autoclave is 5 psi to 20 psi PRESSURE CONTROL: The pressure inside our vertical autoclave is controlled through a semi automatic electro mechanical device called piezostat, which controls the pressure inside the chamber and cuts of the current from the heater whenever the pressure exceeds the set pressure value of the autoclave, thus making it very safe and energy efficient.
Other Specifications Download Specification | |
---|---|
Sterilizer, Shallow (Dressing Drum) Conforming To IS: 3831-1979 | yes |
Weather ISI Marked | No |
If Yes, CM/L No. | N\A |
Material Of Body, Lid & Belt And Hasp | Stainless steel |
Designation Of Stainless Steel | 04Ce18Ni10 to IS:6911-1992 |
Finish Of Stainless Steel | 2B as per IS:6911-1972 |
Shape | Cylirical |
Height Of Sterilizer Mm | 105 mm |
Diameter Of Sterilizer Mm | 80 mm |
Avaliability Of Test Report Fron Govt./ NABL / ILAC Laboratory To Prove Conforming To Specification. | N\A |
Test Report No. And Date | N\A |