First grade quality - virgin material used . Purity of mercury 99.99 due to assured triple distillation process. 0 to 300 mm of Hg scale with elegant finish, fine numbering and durable background contrast paint for clear visibility . Fused type, permanent graduation marking on the glass tube. Special control valve for perfect pressure drop. Best quality cuff for getting excellent grip. Surface plating adapted to all exposed metal parts to prevent corrosion. Classic Hi-stove painting to the body of the instrument to withstand in any climate Optimum damping effect provided for easy and fast measurement.
Other Specifications Download Specification | |
---|---|
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) | Mercurial |
Conformity To Indian Standrad For SPHYGMOMANOMETERS | IS:3390 latest for Mercurial |
ISI MARKED | Yes |
CM/L No And Validity Date | NA |
Measuring Device | Mechnical |
Type | Portable |
Measurement Method | Oscillometric |
Display For Digital BP Instrument: | LCD(Liquid Crystal Digital) Display |
Range: Pressure Measurement | 0 to 300 mmHg |
Range:Pulse Measurement For Digital With Accuracy ± 5%. | 40 to 200 per minute |
Accuracy:Pressure Measurement | ± 3 mmHg |
Pressure Detection | Capacitive Pressure sensor |
Inflation | Manual |
Deflation And Rapid Air Release | Manual |
Cuff Range | Small (18-22)cm |
Dimensions Of The Equipment | 6 mmXmm |
Dimensions Of The Display Screen | 6 mmXmm |
Operating Temperature | 0 to 55 °c |
Stroage Temperature | (-10) to 55 °c |
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). | Yes |
Type Of Battery(4 Nos AA Size) | Alkaline |
Automatic Power Off If System Is Idle For 3 Minutes. | Yes |
Weight | NA Kgs |
CE Marking Certificate For B.P. Apparatus Model. | Yes |
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. | Yes |
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. | Yes |
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " | Yes |
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB | Yes |
Test Cetificate No. | NA |
Test Report Date | NA |
Name And Address Of The Lab Where Test Conducted. | NA |
Others Certificate Ie ROHS,WHO,GMP Etc. | NA |
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. | Yes |
Warranty Time | 1 Year |