insulation multimeter (fluke)(fluke-1587)

` 64,700.00

  • MRP: `81600.00

The Fluke 1587 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Large display with backlight. Insulation testing from 0.01M Ohm to 2G Ohm. Test voltages 50V,100V,250V, 500V, 1000V.Live circuit detection prevents insulation test if voltage is greater than 30V is detected for added user protection. Auto discharge of capacitive voltage for added user protection. Filter for motor drive measurements. CAT III 1000 V, CAT IV 600 V measurement category. 3 Year warranty,.

  • Availability: 4 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Live circuit indicator 30 V to 600v ACDC,50 Hz
Pass Fail Function Yes
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range –20 °C to +55 °C Degree C
Operating Humidity (RH) 0% - 95% (10 °C – 30 °C),0% - 75% (30 °C – 40 °C), 0% - 40% (40 °C – 55 °C) %
Power Requirements Battery Operated
Type Of Battery AA Qty. 04 Nos.
PC Interface Available
Standard Accessories Supplied With The Equipment • Remote probe, Test leads, Alligator clips, K-type thermocouple, Hard case, Four AA alkaline batteries, Quick Reference Guide, CD Rom with Manual,
Dimensions (H X W X L) 203X100X50 mm x mm x
Weight 624 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. Standard
Test Report Date Standard
Name Of The Lab Standard
Warranty 3

Price Dekho Price Dekho Price List in india