× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke-287, industrial true rms multimeter (fluke)(fluke-287)

` 40,996.80

  • Offered Price: ` 43800.00
  • MRP: `66300.00

True RMS Electronics Logging Multimeter with Trend Capture, Fluke 287 packs more accuracy and convenience into a handheld multi meter than ever before, putting more problem solving power in your hands. It is the ultimate handheld tool for demanding applications that require high-precision.Store up to 15,000 recorded events Large 50,000 count, 1/4 VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time,Peak capture to record transients as fast as 250 micro second,Real Time Clock for automatic time stamping of saved readings, CAT III 1000 V / CAT IV 600 V safety rated, Relative mode to remove test lead resistance from low ohms or capacitance measurements, Min/Max/Average with Time Stamp to record signal fluctuations, 0.025 percent Basic DC accuracy, 100 kHz ac bandwidth, Temperature function, Limited lifetime warranty,..

  • Availability: 18 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 4.5 Digit
  • Measurement Type - True RMS
  • Count - 50000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 4.5 Digit
Measurement Type True RMS
Count 50000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy .05 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 100 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 300 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 2 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range -20 degree to 55
Operating Humidity (RH) 0-90%
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery AA Qty. 06
Total Voltage Of Battery 9 Volt
Standard Accessories Supplied With The Equipment Manual , 6AA battery (Installed), Test Lead Set, Alligator Clips
Dimensions (H X W X L) 222X102X60 mm x mm x
Weight 870.9 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. Standard
Test Report Date Standard
Name Of The Lab Standard
Warranty 5 Year

Price Dekho Price Dekho Price List in india