The CXA is todays leading low-cost tool for essential signal characterization. Its capabilities provide a solid foundation for cost effective testing in general-purpose and educational applications. N9000B-526 offers frequency range from 9KHz to 26.5GHz, less than 163dBm DANL and less than 110dBc/Hz SSB Phase Noise at 1GHz, with MULTI-TOUCH USER INTERFACE. With the X-Series, you can perform most operations in two steps or less using the streamlined multi-touch user interface. With X-Series signal analyzers, PowerSuite provides one button measurements of channel power,ACP, OBW, and more. Supplied with pre-amplifier-P26, PFR, B25-25MHz Analysis Bandwidth, fine resolution step attenuator, Rack Mount Flange and Handle, 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. Delivery Period 60 Days..
Other Specifications Download Specification | |
---|---|
Description Of The Item | Spectrum analyzers 26.5GHz |
Frequency Range | 9 kHz to 26.5 GHz |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | Yes |
Frequency Counter Resolution(min.) | 1 Hz |
Frequency Span | 0Hz(zero span),100Hz to 26.5GHz |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | Yes |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | Yes |
Sweep Time @span >or= 1 KHz | 2.6mS to 1000S |
Sweep Time @span = 0 Hz | 10 micro S to 2000 S |
Resolution Bandwidth (-3dB) | 10 Hz to 3 MHz in steps |
Video Bandwidth | 10Hz to 1 MHz in steps |
Amplitude : Max Input Level For Protection | +30 dBm |
Amplitude : Max Input Level For Measurement | +20 dBm |
Amplitude :level Measurement Uncertainity | <or=1 dB |
Average Noise Level Displayed | 300HzRBW,10Hz VBW: |
Markers | Normal and delta |
Trigger | Free run, video, External |
Display | TFT Colour display with provision for three traces |
Interface | USB |
Measurement Features | CN ratio,AM,time domain power measurement,channel power measurement,Phase noise measurement,TOI,OBW |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | Yes |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 3 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | NA Hz |
Return Loss For 2port Vector Network Analyzer | NA dB |
VSWR For 2port Vector Network Analyzer | NA |
Cable Loss For 2port Vector Network Analyzer | NA dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | NA |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | NA |
Phase Range For 2port Vector Network Analyzer | NA degree |
Phase Resolution For 2port Vector Network Analyzer | NA deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | NA dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | NA |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | NA |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | NA |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | NA |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz |
Warranty | 3 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | YES |
Test Report Date | YES |
Name Of Lab | YES |
Address Of The Lab | YES |