Capacity 2KVAInputVoltage Range When load 50, range is 1185VAC2955VAC When 50 load, input range is 1605VAC2955VAC Frequency4654Hz0.5Hz Phase Single Phase Input Power Factor 0.95OutputVoltage208/220/230/240V AC Frequency Range50Hz 0.2THD Liner Load3THD Non-Liner Load5Overload Capability110 30s turn to bypass mode150, 200ms turn to bypass Crest Factor31 max Shot Circuit Protection5 cycles turn off inverter, no transfer to bypass, provide alarm AC mode, 5 cycles turn off inverter, provide alarm battery mode, input fuse blown or breaker actionWaveformPure Sine WaveTransfer time AC to bypass mode4ms typical 2.5msEfficiency8592BatteryDC Voltage72VDC -inbuilt batery 7ah x 6 nosCharge Current0.7A 08ACommunication InterfaceRS232 SNMP optionalLED / LCD IndicationLCD IndicationsNoise Level45dBDimensions Product LxWxH in mm / Net Wt. Product Kg.421 x 190 x 3.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 2 KVA |
Technology | IGBT-PWM |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 30 Minutes |
Minimum VAH | 432 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 4 % |
Overall Efficiency | 93 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NA |
Type Test Certificate Date | NA |
Name Of Lab | NA |
Address Of Lab | NA |
Supply & Commissioning | NA |
Warranty | 1 Years |