Technical Specifications- Microtek 5-Kva online SuperMax series 1 single PhaseModelSupermax-Series - ICapacity5KVA TechnologyDouble Conversion high Freq. Switching PWM, using IGBTsInputVoltage Range160V AC270V AC 5V AC, Single Phase for upto 10KVA and 360V AC450V AC 5V AC, Three Phase for upto 30KVAFrequency4555HzPhaseSingle phase upto 10KVA and Three Phase from 5 to 30KVAGenerator CompatibilityPresentOutputVoltage230V Ac 1Frequency Range50Hz 0.5THD Liner Load3THD Non-Liner Load5Overload Capability125 for 2minuted / 150 for 30SecondsCrest Factor31 maxShot Circuit ProtectionInstantWaveformPure Sine WaveManual BypassInbuilt upto 15KVAStatic Bypass optional5msInverter Efficiency 90 on rated full loadOverall Efficiency 80BatteryDC Voltage180 vdcMimic Control PanelLED for UPS status and LCD for Voltage, Current FrequencyAudible AlarmFor Battery Low / DC High / Output.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 5 KVA |
Technology | IGBT-PWM |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 60 Minutes |
Minimum VAH | 1080 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 3 % |
Overall Efficiency | 93 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NA |
Type Test Certificate Date | NA |
Name Of Lab | NA |
Address Of Lab | NA |
Supply & Commissioning | NA |
Warranty | 1 Years |