Technical Specifications- Microtek 5-Kva online Super Max single Phase ICapacity10KVA Technology Double Conversion high Freq. Switching PWM, using IGBT Input Voltage Range160V AC270V AC 5V AC, Single Phase for upto 10KVA and 360V AC450V AC 5V AC, Three Phase for upto 30KVAFrequency4555HzPhaseSingle phase upto 10KVA and Range 50Hz 0.5THD Liner Load 3THD Non-Liner Load 5O verload Capability125 for 2minuted /150 for 30 Seconds Crest Factor31 max Shot Circuit Protection Instant Waveform Pure Sine Wave Manual Bypass Inbuilt upto 10KVAStatic Bypass optional5msInverter Efficiency 90 on rated full load Overall Efficiency 80 Battery DC Voltage180 vdc Mimic Control Panel LED for UPS status and LCD for Voltage, Current Frequency Audible Alarm For Battery Low / DC High / Output.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 10 KVA |
Technology | MOSFET-PWM |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 60 Minutes |
Minimum VAH | 1080 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 3 % |
Overall Efficiency | 91 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NA |
Type Test Certificate Date | NA |
Name Of Lab | NA |
Address Of Lab | NA |
Supply & Commissioning | NA |
Warranty | 1 Years |