4 pole earth testing.
Other Specifications Download Specification | |
---|---|
Display Type | 3½ digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | YES |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | 4 NOS. |
Material Of The Stakes | Nickel coated iron alloy |
Length Of The Stakes | 30 cm cm |
Diameter Of The Stakes | 1cm cm |
Number Of The Test Leads | 3 nos Nos. |
Length Of The Test Leads | ed- 2500 ,Blue -2500 ,Yellow- 5000 cm cm |
No. Of Test Leads With Clamps | 02 nos Extra cost Nos. |
Length Of Test Leads With Clamps | Red-120 , Black-220 cm cm |
Measuring Range1 For Earth Resistance | 0- 19.99 Ohms Ohms |
Measuring Range2 For Earth Resistance | 20-199.9 Ohms Ohms |
Measuring Range3 For Earth Resistance | 200-1999 Ohms Ohms |
Measuring Range4 For Earth Resistance | 2 kilo Ohm - 9.99 Kilo Ohm Ohms Ohms |
Measuring Range5 For Earth Resistance | 10 Kilo Ohm - 19.9 Kilo Ohm Ohms Ohms |
Measuring Range6 For Earth Resistance | NA Ohms |
Measuring Range7 For Earth Resistance | NA Ohms |
Measurable Earth Resistance Resolution For Range1 | 0.01 Ohms Ohms |
Measurable Earth Resistance Resolution For Range2 | 0.1 Ohms Ohms |
Measurable Earth Resistance Resolution For Range3 | 1 Ohms Ohms |
Measurable Earth Resistance Resolution For Range4 | 0.01 Kilo Ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range5 | 0.1 Kilo Ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range6 | 0 Ohms |
Measurable Earth Resistance Resolution For Range7 | 0 Ohms |
Measurable Earth Resistance Accuracy For Range1 | Range1 +/-2 % + 2 Digits ±% reading ± digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | Range1 +/-2 % + 2 Digits ±% reading ± digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | Range1 +/-2 % + 2 Digits ±% reading ± digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | +/- 5% + 2 digits ±% reading ± digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | +/- 5% + 2 digits ±% reading ± digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | 0 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | 0 ±% reading ± digits |
Stakeless Test(Clamp On) | yes |
Facility To Measure Earth Voltage | Available |
If Yes,Measurable Earth Voltage Range | 0- 100 Volts Volts |
If Yes,Measurable Earth Voltage Accuracy | +/- 2 % + 3 Digits % % |
Minimum Open Circuit Output Voltage | less tha 24 Volts RMS Volts Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | 1 Volts Volts |
Internal Memory | less tha 24 Volts RMS Volts |
Type Of Battery Used In The Power Supply | Ni Mh |
Battery Backup Time | 5-6 hours Hours Hours |
Battery Charger Provided With The Meter. | Yes |
Weight Of The Tester | 2500 grams grams |
Dimensions(LXWXH) | 29 x 22 x 7.5 cmXcmXcm cmXcmXcm |
Provision For External SD Card | No |
Interface | USB |
Operating Temperature Range | -10 to 50 degree celsius degree celsius |
Operating Humidity Range | 20 to 80 % % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | 40000 |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | yes |
TTC Report Date | yes |
Name Of Lab | yes |
Address Of Lab | yes |