Power Quality Analyzer (Hioki)(PW3198)

` 576,000.00

  • MRP: `640000.00

PQA for Single Phase-2 wire and 3 wire, Three Phase 3 wire and 4 wire, DC Measurement, Transient Measurement 6000V, Current 500 ma to 5.0000kA, 6.5 inch TFT color display 640 x 480 dots. Accessories Include Instructional Manual, Measurement Guide, Voltage Cord one set, AC adapter Z1002, USB cable, Battery Pack Z1003, SD memory card 2GB Z4001, Carrying Case C1001. Clamp on Sensor 500A AC 9661 x 4nos included.

  • Availability: 4 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - 6.5-inch TFT color LCD (640 × 480 dots)
  • Number of Current Channels - 4 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 0.01 Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type LCD Backlit
Display Mode 6.5-inch TFT color LCD (640 × 480 dots)
Number Of Current Channels 4 Nos.
Number Of Voltage Channels 4 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 600.00 V rms Volts
Measurable Voltage Accuracy ±0.1% of nominal voltage
Measurable Voltage Resolution 0.01 Volts
Facility To Measure RMS Current Available
Measurable Current Range 5.0000 kA AC (depends on current sensor in use) Ampere
Measurable Current Accuracy ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurable Current Resolution 0.01 mA ( Depend on Clamp Sensor Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 300.00 W to 3.0000 MW KW
Power Accuracy ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Power Resolution 0.01 W Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 700 Hz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion 1
Resolution In Measurement Of Total Harmonics Distortion 0.01
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available up to 50th Order
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor 1
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor 1
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor 0
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range Voltage : 2, Transient Over Voltage : 1, Current : 4
Measurable Crest Factor Accuracy 1
Measurable Crest Factor Resolution 1
Screen Memory 1
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory 2 GB to 32 GB MB
Type Of Battery Used Lithium Battery
Battery Backup 3 Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 2.6 KG Grams
Dimensions(LXWXH) 3000 W× 2110 H × 680 D cm cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range 0 to 50 degree celsius
Operating Humidity 80 %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Instruction manual, Measurement guide, VOLTAGE CORD L1000 (8 cords, approx. 3 m each: 1 each red, yellow, blue, and gray plus 4 black; 8 alligator clips: 1 each red, yellow, blue, and gray plus 4 black), Spiral Tube, Input Cable Labels (for identifying channel of voltage cords and clamp-on sensors), AC ADAPTER Z1002, Strap, USB cable (1 m length), BATTERY PACK Z1003, SD MEMORY CARD (2GB) Z4001
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating 600 V CAT III
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. NA
TTC Report Date NA
Name Of Lab NA
Address Of Lab NA
Interface SD Memory Card, USB, RS-232C and LAN

Price Dekho Price Dekho Price List in india