The GDM-360 Hand Held DMM are a compact, high precision, battery operated multimeter designed to meet most of the daily needs for design engineers as well as service engineers. The GDM-360 design is driven by mobile-oriented features, such as automatic power down to preserve battery life, a large backlight display for crisp viewing, a rotary selector switch and clear-cut push buttons to ease operation.The basic functions match the depth of bench-top multimeters fuse-protected current input, true RMS for accurate AC measurements, Auto ranging, Duty cycle, and Relative mode. These compact, reliable, and economical devices are ideal for any engineer. Prices indicated including GST @18 percent...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1.5 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 200 Micro Fara |
Capacitance Measurement Accuracy | 2.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0°C to 50°C |
Operating Humidity (RH) | ≤80% |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
If Battery Operated, Type And No. Of Battery | Single 9V Battery (6F22) |
Total Voltage Of Battery | Single |
Standard Accessories Supplied With The Equipment | Test Leads, Probe Holders, Batteries |
Dimensions (H X W X L) | 8.7 x 4.7 x 18 cm mm x mm x |
Weight | 380 g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | PMR |
Test Report Date | 10/06/2017 |
Name Of The Lab | Factory Calibration |
Warranty | 1 Year |