15 kva on-line ups 3phase in 3 phase out 60min backup 24000vah (orion)(orion 15 kva 60 min 3 in 3 out)

` 317,670.00

  • MRP: `381206.00

15 KVA 3 Phase AC in 3 Phase AC out On-Line UPS with isolation transformer, Floor Mounted UPS with 65ah X 31 Nos battery Total VAH24000for 60 minutes backup@ 95 efficiency , BATTERY WARRANTY 2 year replacement, make EXIDE/ ROCKET/HBL, UPS warranty 2 year, static bypass also availableWe are having PAN India after Sales Service Network, tested from ETDC- STQC NABL accredited Central Govt. Laboratory.

  • Availability: 51 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - 3 phase 400 V ±1% with alternative user setable setting of 380V+-1%,50Hz
  • Minimum VAH - 24000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 15 KVA
Technology IGBT-PWM
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power 3 phase 400 V ±1% with alternative user setable setting of 380V+-1%,50Hz
Backup Time 60 Minutes
Minimum VAH 24000 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 30 %
Overall Efficiency 91 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. AS PER OEM SUBMITED
Type Test Certificate Date AS PER OEM SUBMITED
Name Of Lab AS PER OEM SUBMITED
Address Of Lab AS PER OEM SUBMITED
Supply & Commissioning YES, AS PER REQUIREMENT
Warranty 2 Years