Pioneers in advanced Fire Fighting solutions, Vimal Fire Controls Pvt. Ltd. introduces Portable Fire Extinguishers made up of Lightweight Aluminium Extrusion. By its natural properties, the Aluminium based cylinder is almost 30 lighter and hence easier to lift and rush for firefighting. Being Aluminium, they are highly suitable for corrosive and humid atmospheric conditions. The fire extinguishers are made of seamless construction with no weld joints, and these make them far more robust as compared to MS body cylinders. Due to no weld joints, they are even safe while operation since no chances of body leakage and also meagre chance of rejection / scrapping due to leakage from weld joints after few years. 9 Kg Aluminium Body Fire Extinguisher with Dry Chemical Powder ABC has the highest Fire rating of up to 6A, 89B. Vimal provides 10 years of warranty on this product. ABOVE ALL, THE SAID FIRE EXTINGUISHERS COMES WITH ISI BIS MARKING AS PER IS15683.
Other Specifications Download Specification | |
---|---|
Conformity To Standard | IS:15683:2006 With Latest Amdmnt. |
BIS Marking | Yes |
CM/L No. With Validity Period | 3731054 1-Year |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | ABC |
Clean Agents Based Extinguishing Media | NA |
Expellant Medium | N2 Based |
Fire Extinguisher Capacity( Foam Based/Water Based) | NA Ltrs |
Powder Based Fire Extinguisher Capacity | 9 Kg |
Carbon Dioxide Based Fire Extinguisher Capacity | NA Kg |
Clean Agents Fire Extinguisher Capacity | NA Kg |
Weight Of Filled Portable Fire Extinghuisher | 12.2 Kg |
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) | 35 Bar |
Burst Pressure,Min | 55 Bar |
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) | 7 Meters |
Effective Discharge Time For Fire Extinguisher, Min | 25 Seconds |
Fire Rating For Class -A Fire Extinguisher | 6A |
Fire Rating For Class -B Fire Extinguisher | 34B |
Fire Extinguisher Suitable For Class -C Fire | YES |
Fire Extinguisher Suitable For Class -D Fire | NO |
Fire Extinguisher Suitable For Class -K Fire | NO |
Rechargebale | YES |
Color Coding | Red |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | 3731054 |
Test Report Date | 11-01-2017 |
Name Of The Lab | Fire Test & Research Laboratories |
Address Of The Lab | 9 Milesstones Sonipat Haryana |
Operating Temperature | +5° C to + 55° C ° C |
Fire Extinguisher Suitable For Class -E Fire | YES |