× All the transactions performed on 2.0 is available here. To access Market click "Home".

model traffic light (accurate)(asim-tl)

` 1,080.00

  • MRP: `1200.00

This traffic light is made with the help of counter IC, which is mainly used for Sequential Circuits. We can also call it as Sequential Traffic Lights. Sequential Circuits are used to count the numbers in the series.Coming to the working principle of Traffic Lights, the main IC is 4017 counter IC which is used to glow the Red, yellow and green LED respectively. 555 timer acts as a pulse generator providing an input to the 4017 counter IC. Timing of glow of certain lights totally depends upon the 555 timers pulse, which we can control via the Potentiometer so if you want to change the time of glow, you can do so by varying the potentiometer, having the responsibility for the timing...

  • Availability: 250 In Stock
  • Min. Qty. Per Consignee: 36
  • DC Current Output Rating - 0 to 4 Ampere
  • Maximum Power - 120 Watt
  • Load Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 2 mV
  • Line Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 1 mV
  • Over Voltage Protection Response Time - less than 10 milli sec
Other Specifications Download Specification
DC Voltage Output Rating 0 to 30 Volt
DC Current Output Rating 0 to 4 Ampere
Maximum Power 120 Watt
Load Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 2 mV
Load Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 1.5 mA
Line Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 1 mV
Line Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 0.1 mA
Over Voltage Protection Accuracy +- 0.5 + 0.5 V
Over Voltage Protection Response Time less than 10 milli sec
Ripple And Noise Voltage (20 Hz To 20 MHz) less than 1 mVrms less than 4 mVpp
Ripple And Noise Current (20 Hz To 20 MHz) less than 4 mArms
Readback Voltage Accuracy 0.05 + 10 mV
Readback Current Accuracy 0.15 + 4 mA
Readback Voltage Resolution 1 mV
Readback Current Resolution 0.1 mA
Operating Temperature 0-50 Degree C
Gperating Humidity (RH) N/A %
PC Interface USB
Dimensions N/A mm x mm x
Weight GPIB gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. N/A
Test Report Date N/A
Name Of The Lab N/A
Warranty 1 Year

Price Dekho Price Dekho Price List in india