Salient Features - 8 Equal Zones from Top to Bottom,PVC Coated Frame All Weather Proof,Microprocessor Based with PC Connectivity.Multi Zone Detection Eight Zone. AUTO SET.Detector is continuously active.Self diagnosis. Display of time,counter,program setting, sensitivity setting. Multi-mode counter IN/OUT/NET . Sensitivity setting of individual zone./All zones. Keypad for all program settings. Inbuilt Battery Back up to 12 hrs. Remote Programming optional. Safety Parameter tested with Electronics Lab. CE Marking. Technical Specifications - Floor space required 585 x 820 sq.m Approx, Net Passage Clearance Height -1850-2050 mm approx, Width 700-760 mm approx, depth 500-570 mm.Approx, Overall frame assembly Height 2000-2220 mm,Width 800-880mm approx, depth 500-570 mm approx,Weight 65 Kg Approx. Power- 230 VAC 15 50 Hz,50 VA , Operating Temperature -20 degree celcius to 60 degree celcius, Humidity - 95 percent Non Condensing..
Other Specifications Download Specification | |
---|---|
Technology | PI & CW |
Walk-through Arch (Outer Frame) Dimensions (H X W X D) | 2300 X 870 X 510 mm mmxmmxmm |
Walk-through Arch (Inner Frame) Dimensions (H X W X D) | 2000 X 720 X 510 mm mmxmmxmm |
Detection Area (H X W X D) | 2000 X 720 X 510 mm mmxmmxmm |
Detection Zones | Multiple Zones |
Number Of Detection Zones | 8 ZONE |
Type Of Usage | Outdoor |
"Construction Of Door Frame (Walk-through Arch)" | Light weight, rigid, laminated side panels and cross piece with ABS plastic boots for panel protection |
Door Frame Is Provided With Base Wheels For Easy Mobility | YES |
Door Frame Is Provided With A Floor Panel To Attach Both Side Panels To Give Stability & Rigidity To The Structure | YES |
Ramp Over The Floor Panel - Covered With Synthetic Carpet For Long Life | YES |
Door Frame Material | PVC side panels & top head unit. High in strength & light in weight |
Door Frame Is Water Proof | YES |
Door Frame Is Weather Proof | YES |
Operational Frequency Range | 8 KHz to 30 KHz |
Number Of User Selectable Frequencies | 10 level |
Adjustable Sensitivity | YES |
Number Of Sensitivity Levels / Steps | Multi-program setting for over all zones & 0-255 level for individual zone setting for over all zones & 0-255 level for individual zone setting |
Metals Which Can Be Detected | Ferrous, Non-Ferrous, Ferrite & Alloys |
Capability Of Metal Detection In Entire Frame Area | Uniformly in entire Frame Area |
Capability Of Metal Detection In All Orientations | YES |
Capability Of Metal Detection In Walking Speed Of Interception | YES |
Audio-Visual Indication On Detection At Side Panels And Control Panel | YES |
Audible Alarm On Detection With Adjustable Volume | YES |
Back-lit Display | LCD |
Display Of Zone Intercepted | YES |
False Alarm Rate | Less than 3% % |
Traffic Counter (inbound / Outbound) For Counting Number Of Persons Passing The Sensing Zone | YES |
Walk / Stop Indicator For Traffic Control | YES |
DFMD Should Not Interfere With Adjacent Installed DFMDs Within A Distance Of 1 Foot | YES |
DFMD Should Not Be Affected By Opening / Closing Of A Metallic Gate In Vicinity | YES |
DFMD Should Not Be Affected By Heavily Reinforced Floors / Roof Tops / Walls | YES |
DFMD Should Not Be Affected By External RF Transmission And EMI (Electro Magnetic Interference) | YES |
Capacity / Throughput Rate | 25 person/Mini approx. person/min |
In-built Auto Calibration Capability | YES |
User Friendly Self-testing Diagnostics To Identify Faulty Condition | YES |
Control Panel | Easy accessible control panel, with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and / or by password. |
Power Supply | 220 V AC, 50 Hz, Mains + 10 |
Battery | Re-chargeable, maintenance free, in-built battery with charger |
"Details Of Battery / UPS (Type / Make / Capacity -VAH, Etc)" | 12 V 4.5 / 7 APH Rechargeable battery inbuilt |
Battery Back-up In Full Function | 10 to 12 Hrs. hours |
Audio-Visual Low Battery Indicator | YES |
DFMD Should Be 'Data Safe' | YES |
DFMD Shall Be Harmless To Wearers Of Pacemakers, Defibrillators Or Other Vital Support Systems, Pregnant Women And Magnetic Storage Media (floppy Disks, Audio Cassettes, Video Cassettes And Similar) | YES |
DFMD Should Conform To International Security Standards Of Safety / Radiation | YES |
Warranty | 3 Years |
One Test Sample For Each Machine For Tesgting During Commissioning / Maintenance | Inclusive in the scope of supply |
Training Tools- Charts, Slides, Training Brochure, Training Work Model, Blowup Diagram, Video Films On Demonstration And Use Etc. | Inclusive in the scope of supply |
Technical Manual Giving Full Description Of The Item, User's Handbook And Literature On Preservation / Maintenance, Procedure For Packing, Handling, Transportation, Storage And Battery Replacement | Inclusive in the scope of supply |
Practical Training | At least one day in each quarter of the year continuing during warranty period |
Operating Temperature Range & Relative Humidity | -20 deg C to 60 deg C, Humidity 95% RH (non-condensing) |
Availability Of Spares For A Period Of 7 Years After The Warranty Period | YES |
Availability Of Test Reports From Central Govt / NABL / ILAC Accredited Lab Covering All The Parameters As Per Specifications | YES |
Test Report No. | PCMTL/1007-1009/2017 |
Name Of Test Lab | PHYSI CHEM MATERIAL TESTING LABORATORY |
Address Of Test Lab | Udyogswamini Prerana Sankul, Plot No A-17, Gala No. 15 MIDC, Ambad, Nashik - 422010 |
Hyper Link To Test Report | physichem_2008@rediffmail.com |