× All the transactions performed on 2.0 is available here. To access Market click "Home".

iron and hardness removal plant (susitech)(irph2000)

` 249,999.00

  • MRP: `280000.00

IRPH2000.

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • Prefilter Provided with Flushing Valve in the Iron Removal Unit - NO
  • Iron Removal Unit Suitable for Water Supply Equipment - Tubewell
  • Discharge Capacity of the Iron Removal Equipment - 2000 LPH LPH
  • Diameter of Vessel of Iron Removal Equipment - 354+/-30mm mm
  • Minimum Thickness of Vessel of Iron Removal Equipment - NA mm mm
Other Specifications Download Specification
Iron Removal Unit Without
Prefilter Provided With Flushing Valve In The Iron Removal Unit NO
Iron Removal Unit Suitable For Water Supply Equipment Tubewell
Discharge Capacity Of The Iron Removal Equipment 2000 LPH LPH
Material Of Body Of Iron Removal Equipment FRP
Diameter Of Vessel Of Iron Removal Equipment 354+/-30mm mm
Height Of Vessel Of Iron Removal Equipment 1645+/-30mm mm
Number Of Iron Removal Vessel 1Nos Nos
Minimum Thickness Of Vessel Of Iron Removal Equipment NA mm mm
Material Of Strainer Plate Of Iron Removal Equipment NA
Diameter Of Strainer Plate Of Iron Removal Equipment NA mm mm
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment NA mm mm
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment NA Nos Nos
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment NA Nos Nos
Material Of Strainer In Strainer Plate Of Iron Removal Equipment NA
Quantity Of Iron Removal Media In Iron Removal Vessel 70kg Kg
Quantity Of Filter Media In Iron Removal Media 42kg Kg
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel 25%
Back Wash Valve In Iron Removal Vessel Automatic Operated Valve System connected to Electric Supply and operated by a timer
The Accumulated Ferric Is Removed From The Media While Back Washing YES
Maximum Iron Content Of Inlet Water 15ppm ppm
Maximum Iron Content Of Outlet Water 0.3 ppm
Process By Which Iron Is Removed From Water By Iron Removal Media MEDIA WORKS ON OXIDATION PROCESS
Life Of Iron Removal Media 3Years Years
Cost Of Refilling Of Iron Removal Media 405.00 per kg Rupees Rupees
Life Of Iron Removal Unit 6 Years Years
Protective Coating Of Iron Removal Vessel ultra violet
Inlet Pipe Size Of Iron Removal Unit 38mm mm
Space Required For Installation Of Iron Removal Unit 1.5x1.5 Square Meters Square Metres
Number Of Valves In Iron Removal Unit 1 nos Nos
Materal Of Valve Of Iron Removal Unit ABS
Diameter Of The Valve In Iron Removal Unit 25mm mm
Pressure Gauge In Iron Removal Unit YES
Pressure Release Valve In Iron Removal Unit YES
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit 6kg/cm2 kg/square cm Kg/square cm
Weight Of Iron Removal Unit approx 130 kg Kg
Warranty Period Of Iron Removal Unit 1 Years Years
Arsenic Removal Unit Without
Discharge Capacity Of The Arsenic Removal Unit 0LPH LPH
Arsenic Removal Unit Suitable For Water Supply Equipment Tubewell
Material Of Arsenic Removal Vessel 0
Diameter Of Arsenic Removal Vessel 0mm mm
Height Of Arsenic Removal Vessel 0mm mm
Minimum Thickness Of Arsenic Removal Vessel 0mm mm
Number Of Arsenic Removal Vessel 0Nos Nos
Material Of Strainer Plate Of Arsenic Removal Vessel 0
Diameter Of Strainer Plate Of Arsenic Removal Vessel 0mm mm
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel 0mm mm
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate 0Nos Nos
Material Of Strainer In Arsenic Removal Strainer Plate 0
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel 0kg Kg
Media Used For Removal Of Arsenic From Water 0
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel 0
Maximum Arsenic Content Of Inlet Water 0ppm ppm
Maximum Arsenic Content Of Outlet Water NA ppm
Life Of Arsenic Removal Media 1 Years Years
Cost Of Refilling Of Arsenic Removal Media 0 Rupees Rupees
Life Of Arsenic Removal Unit 0 Years Years
Protective Coating Of Arsenic Removal Vessel 0
Inlet Pipe Size Of Arsenic Removal Unit 0mm mm
Space Required For Installation Of Arsenic Removal Unit 0 Square meters Square Metres
Number Of Valves In Arsenic Removal Unit 0 Nos Nos
Materal Of Valve In Arsenic Removal Unit 0
Diameter Of The Valve Of Arsenic Removal Unit 0mm mm
Pressure Gauge In Arsenic Removal Unit NO
Pressure Release Valve In Arsenic Removal Unit NO
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit 0kg/ square cm Kg/square cm
Weight Of Arsenic Removal Unit 0kg Kg
Warranty Period Of Arsenic Removal Unit 0 Yeares Years
Iron Removal Media Conform To International Standard National Science Foundation, USA
Arsenic Removal Media Conform To International Standard National Science Foundation, USA
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate YES
Field Testing Kit For Testing Iron & Arsenic Is Provided YES

Price Dekho Price Dekho Price List in india