× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital insulation tester with pi (motwane)(it-51)

` 58,030.00

  • MRP: `78000.00

The Motwane IT-51 is a microprocessor based Digital Insulation tester designed for testing of all types electrical installation like transformers, switchgear, motors, generators and utility substation equipments. The instrument automatically performs Polarization index by selecting PI mode. IT-51 has a large LCD blue backlit display, it shows leakage current in scrolling form along with IR value and PI value. It is rechargeable battery operated and AC mains provision for battery charging..

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 3
  • Measurement Range - 200 K Ohm to 1 T Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 200 K Ohm to 1 T Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging NA
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range -10°C to 55°C Degree C
Operating Humidity (RH) 95 %
Power Requirements Battery Operated
Type Of Battery Rechargeable battery Lithium Ion
PC Interface Available
Standard Accessories Supplied With The Equipment No
Dimensions (H X W X L) 195x290x360 mm x mm x
Weight 5000 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1

Price Dekho Price Dekho Price List in india