The Motwane had been offering comprehensive range of products designed in-house catering multiple segment of power and energy sector. Being pioneer in insulation testing the IT250G SPOT is a 5KV voltage selectable digital insulation tester measures digitally and also in analog. It is a battery operated most compact device made to give stable and reliable performance in energy intensive area. Auto power off enhance battery life and pleasant amber backlit allows user to work in dusk environment also. It is ideally suited for many troubleshooting, installation commissioning in electrical Substations and preventative maintenance on both domestic industrial applications. IT250G is an ideal suited for onsite testing..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | NA |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | 0°C to 50°C Degree C |
Operating Humidity (RH) | 90 % |
Power Requirements | Battery Operated |
Type Of Battery | 1.5V AA Size Alkaline Batteries |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | No |
Dimensions (H X W X L) | 230x165x95 mm x mm x |
Weight | 1500 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM |
Warranty | 1 |