This is a highly advanced insulation tester for diagnosing insulation resistance of all types of electrical equipments. The meter is equipped with programmable test voltage of 250V-5000V DC available with resistance measurement upto 10 T. The instrument automatically performs PI, DAR, DD, Step Voltage with Stand Voltage test in the diagnostic modes, enabling consistent operation simultaneously it can store the readings in the memory that can be downloaded to PC, through RS 232 interface, with the help of software provided. This meter has fast settling time less than 10 second, Digital Analog display of readings, LCD display with pleasant blue backlit, Built in memory to store upto 1000 test result. The meter is operated on mains plus battery and it is IP 54 protected..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | NA |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | 0°C to 55°C Degree C |
Operating Humidity (RH) | 95 % |
Power Requirements | Battery Operated |
Type Of Battery | NA |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | No |
Dimensions (H X W X L) | 195x290x360 mm x mm x |
Weight | 5000 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM |
Warranty | 1 |