GWINSTEK GDS-3502 500 MHz,2CH DSO, 4GSa/s sampling rate and VPO waveform display with split screen feature for multi-window multi-signal tests in the research and the manufacturing fields. The optional power analysis software and the optional serial bus analysis software are available to facilitate the engineers tasks in testing and manufacturing of the associated products. The unique split screen feature of GDS-3502 allows each input channel to be operated independently with respective setting and waveform display. The time base, the vertical sensitivity, and the trigger selections can be done by each channel separately. The 8-inch high resolution 800x600 LCD display makes the split screen a pleasant observation environment to view the details of complex signals. Three input impedance, 1M, 75, 50 E are available for users selection.Pl Refer GW-INSTEK datasheet for detailed specifications. Prices indicated including GST. Standard Delivery Period is 30 Days.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, GND |
Time Base Range | 1ns/div ~ 100s/div (1-2-5 increments) |
Trigger Types | Edge, Pulse Width, Video, Pulse Runt, Rise & Fall, Timeout, Alternate, Glitch Trigger, Duration Trigger, Slope Trigger, Event-Delay(1~65535 events), Time-Delay(Duration, 4nS~10S) and external trigger |
Measurements | 28 sets of Automatic Measurements, Time & Voltage Cursors, Math (Add, Subtract, Divide, Multiply, Integration, Differentiation), FFT, FFTrms |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Average, Peak Detect, High Resolution, Single. |
Display Type | Colour |
Display Size | 20.3 CM |
I/O Interface | 2 sets of USB 2.0 High-speed host port, 1 set of USB High-speed 2.0 device port, LAN (Ethernet), RS-232C, SVGA Video Port, Go/NoGo BNC |
Standard Accessories To Be Supplied | Two 10X Passive probes, Power Cord, Manual, Calibration Certificates |
Operating Temperature Range | 0°C to 50°C Degree C |
Operating Humidity (RH) | ≤80% % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | ETDC MH /T&M/110 |
Test Report Date | 17/08/2015 |
Name Of The Lab | ETDC MOHALI |
Warranty | 3 Year |
Real Time Bandwidth | 500 MHz |
Record Length Per Analog Channel Simultaneously | 25k on all channels simultaneously (25K per Channel) Mega Point |
Sample Rate Per Analog Channel Simultaneously | 4GSa/s GS/sec |
Waveform Update Rate | 3500 Waveforms/ |
Time Base Accuracy | 20 PPM |