× All the transactions performed on 2.0 is available here. To access Market click "Home".

online ups 10 kva 192v without Batteries (microtek 10 KVA 192v WITHOUT BATTERIES)(microtek 10 KVA 192v WITHOUT BATTERIES)

` 76,786.00

  • MRP: `86990.00

MICROTEK 10KVA, 192V ONLINE UPS, WITHOUT BATTERIES. Microtek Hi-End Jumbo UPS 10 KVA is designed to take Higher Loads. It runs Load up to 8 Kilowatts It is the best suited UPS for High Capacity Sophisticated.True Online Double Conversion Technology High End IGBT based High End Micro Controller. Automatic Battery Charging in UPS Off Mode Wide Input Voltage Range Advanced Battery Management Short Circuit and Overload Protection Hot Standby Optional Galvanic Isolation Available at Output1 Phase In 1 Phase out. Specially Designed to Suit Indian Power and Environment Conditions Generator Compatible Over Temperature Protection..

  • Availability: 25 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 0 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 10 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 0 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 93 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. as per manufacturer
Type Test Certificate Date as per manufacturer
Name Of Lab as per manufacturer
Address Of Lab as per manufacturer
Supply & Commissioning Yes
Warranty 1 Years

Price Dekho Price Dekho Price List in india