We are providing a excellent quality of Digital Oscilloscopes OS5030 which is now the preferred type for most industrial applications. Instead of storage-type cathode ray tubes, DSOs use digital memory, which can store data as long as required without degradation. A digital storage oscilloscope also allows complex processing of the signal by high-speed digital signal processing circuits. Its advantage are brighter and bigger display with color to distinguish multiple traces as well as equivalent time sampling and averaging across consecutive samples or scans lead to higher resolution down to V..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | NA Number |
Digital Channels | Yes |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | Build-in 6 Digit Frequency Counter GS/sec |
Sampling Rate Per Digital Channel Simultaneously | 30MHz Dual Channel Mega Points |
Min. Detectable Pulse Width | 0 ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | Low limit frequency 10Hz. (With reference to 100KHz, 8DIV, Frequency response with-3dB. |
Time Base Range | 0 |
Trigger Types | YES |
Measurements | AS PER OEM |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | Yes |
Acquisition Modes | AS PER OEM |
Display Type | Colour |
Display Size | 8×10 DIV [1DIV=10mm(0.39in)]; CM |
I/O Interface | AS PER OEM |
Standard Accessories To Be Supplied | NA |
Operating Temperature Range | -10C to 50C Degree C |
Operating Humidity (RH) | 0 % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 1 Year |
Real Time Bandwidth | 20 MHz |
Record Length Per Analog Channel Simultaneously | NA Mega Point |
Sample Rate Per Analog Channel Simultaneously | NA GS/sec |
Waveform Update Rate | 0 Waveforms/ |
Time Base Accuracy | 0.05 PPM |