HTC Thermo Anenometer Key Features 0.5 Inch 13mm 4 Digit LCD Display Data Hold Data Memory 24 groups Auto Power OFF Optional RS-232 Communication Advanced Software Program for all windows Special Functions Air Velocity/ Flow Sensor Conventional angled Vane arm with low Friction ball bearing Temperature Sensor Precision thermistor Optional Accessory HTC RS-232 Cable with Software ,RS-232 USB Cable Air Velocity m/s meter/Second , km/h kilometers/Hour , Ft/min Feet/minute, Knots Nautical MPH Air Flow CMMm/min , CFM ft/min Beaufort Scale 0-12 Wave Height 0-14, Air Velocity Range 0.40-450 m/s Air Velocity Resolution-0.1 m/s Air Velocity Accuracy-2 0.1m/s Air Flow Range-0-9999 m/min Air Flow Resolution-0.001-1Air Temperature Range0 to 60 C Air Temperature Resolution 0.1C Air Temperature Accuracy-0.5C Display-4 Digits LCD Display Operating Environment 0 to 50 C Auto Power Off 0-9 Min Set by User Power Supply 4 x1.5 V AAA Size Battery Dimensions 156x67x28 mm..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Single phase |
Display Type | LCD Backlit |
Display Mode | Digital |
Number Of Current Channels | 1 Nos. |
Number Of Voltage Channels | 1 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 0.1 Volts |
Measurable Voltage Accuracy | 0.1 |
Measurable Voltage Resolution | 0.1 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 1 Ampere |
Measurable Current Accuracy | 1 |
Measurable Current Resolution | 2 Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 10 KW |
Power Accuracy | 20 Amp |
Power Resolution | 15 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 0.1 Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | 0.1 |
Resolution In Measurement Of Total Harmonics Distortion | 0.1 |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 0.1 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | 1 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | 0.1 |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | 0.1 |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1 |
Measurable Crest Factor Accuracy | 0.1 |
Measurable Crest Factor Resolution | 0.1 |
Screen Memory | 24 |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 1024 MB |
Type Of Battery Used | 9 AAA Micro Batteries |
Battery Backup | 10 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 500 Grams |
Dimensions(LXWXH) | 15.6 x 6.7x2.8 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0-40 degree celsius |
Operating Humidity | 95 % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Sensory probe, Hard Carrying Case, Manual |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT-III 1000V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 21454 |
TTC Report Date | 21-05-2017 |
Name Of Lab | Star Labs |
Address Of Lab | Delhi |
Interface | No |