Analysis for single phase and balanced 3 phase system True RMS Value Voltage Current Large LCD Display with Backlight USB interface Min/Max measurement True Power/Apparent power/ power factor measurement Data Hold/ Auto ranging / Overflow indication/ Auto power Off 2.1655mm Jaw opening. Frequency 20Hz-200Hz, 0.5 percent 5Energy 1-9999k Wh, 3 percent 2 Power Factor 0.3-1, 2 percent 20Standard Accessories - Test lead, gifts box carrying case and 9V battery, USB cable Dimension 295 H x 100 W x 46 D millimeter.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 55 |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | 0-65 Degree C |
Operating Humidity (RH) | 85 % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
Standard Accessories Supplied With The Equipment | yes |
Dimensions (H X W X L) | 180x123x50 mm x mm x |
Weight | 2.5 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 32568 |
Test Report Date | 21-05-2017 |
Name Of The Lab | Star Labs |
Warranty | 1 Year |