GWINSTEK GDS-2104E Digital Storage Oscilloscope 100 MHz BW,4 CH model provides 1GSa/s real-time sampling rate for each channel. The 8-inch 800480 TFT LCD display and the minimum 1mV/div vertical range allow the GDS-2104E to measure complex feeble signals and clearly display measurement results. the GDS-2104E provides 10M long memory for users to completely retrieve and analyze waveforms. Users, based upon the application requirements, can select 1K, 10K, 100K, 1M or 10M memory depth. Short memory depth collocating with the high sampling rate allows users to observe fast-changing waveforms and, on the other hand, long memory depth aims for continuously changing waveforms. equipped with waveform search and segmented memory functions. Prices indicated including GST. Standard Delivery Period is 30 Days.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC DC GND |
Time Base Range | 1ns/Div ~ 100s/Div (1-2-5 Increments) |
Trigger Types | Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate, Time Out, Event-Delay (~65535 Events), Time-Delay (Duration,4nS~10S), Bus |
Measurements | utomatic Measurements: 36 Sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROV Shoot, FOV Shoot, RPRE Shoot, FPRE Shoot, Frequency, Period, Rise Time, Fall Time, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase. Waveform Signal Process: Plus, -, ×, ÷, FFT, FFTrms, User Defined Expression. Cursors For Amplitude, Time, Gating Available |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Average, Peak Detect, Single |
Display Type | Colour |
Display Size | 20.3 CM |
I/O Interface | LAN, Go/NoGo BNC, USB 2.0 High-Speed Host Port X 1, USB High-Speed 2.0 Device Port X 1. The PC Software "OpenWave" Available. |
Standard Accessories To Be Supplied | Four 10X Probes, Power Cord, Manual,To Be Supplied Calibration Certificates |
Operating Temperature Range | 0°C to 50°C Degree C |
Operating Humidity (RH) | ≤80 % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | PMR |
Test Report Date | YES |
Name Of The Lab | GWINSTEK FACTORY |
Warranty | 3 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | 10M Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/S GS/sec |
Waveform Update Rate | 120,000 Waveforms/ |
Time Base Accuracy | 50 PPM |