× All the transactions performed on 2.0 is available here. To access Market click "Home".

dit 954 digital insulation tester (meco)(dit 954 digital insulation tester)

` 13,029.00

  • MRP: `14477.40

MECO- DIT 954 is a 5KV Digital Insulation Tester with 3 1/2 Digit, 1999 Counts, Large Display and Backlight. It Measures Insulation Resistance upto 200G Ohm, AC Voltage upto 600VAC and checks Phase sequence.

  • Availability: 95 In Stock
  • Min. Qty. Per Consignee: 5
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range 0 Degree Celsuis to 40 Degree Celsius Degree C
Operating Humidity (RH) . %
Power Requirements Battery Operated
Type Of Battery 1.5V AA Battery
PC Interface Available
Standard Accessories Supplied With The Equipment Insulation Resistance Measurement Test Leads for High Voltage X 1 Set Phase Sequence Measurement wires X 1 set AC Adaptor X 1, 1.5V AA Batteries X 8 Heavy Duty Carry Case X 1 Instruction Manual X 1
Dimensions (H X W X L) 190 X 155 X 75mm mm x mm x
Weight 900gms gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. .
Test Report Date .
Name Of The Lab .
Warranty 1

Price Dekho Price Dekho Price List in india