Safety CAT III 1000V / CAT IV 600V Standards IEC61000-4-30 2008 S class,EN50160 2007. Easy operation to capture the power quality problem. Single-phase 2W / Single-phase 3W / 3-phase 3W / 3-phase 4W. Display Run Chart, Bar Chart, Vector Graphic,Waveform, Event List, Readings. 8G Memory Card to Make the long-term measuring data storage. Support USB port to connect to PC and analyze the data / screen shots copied by U-disk. Support LAN port to make the remote control available, transfer the measuring data..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | digital |
Number Of Current Channels | 3 Nos. |
Number Of Voltage Channels | 3 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1000 Volts |
Measurable Voltage Accuracy | +/- 0.5% |
Measurable Voltage Resolution | 0.1V RMS Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 3000 Ampere |
Measurable Current Accuracy | +/- 1% |
Measurable Current Resolution | 1A RMS Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 200 GWH KW |
Power Accuracy | +/- 1.5 |
Power Resolution | 0.1 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 69 Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | 1 |
Resolution In Measurement Of Total Harmonics Distortion | 1 |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | +/- 0.1 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | +/- .03 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | +/- 5% |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | 1 |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1.0-2.8 |
Measurable Crest Factor Accuracy | +/- 5 |
Measurable Crest Factor Resolution | .01 |
Screen Memory | 1 |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 8G MB |
Type Of Battery Used | 4.4AH LI-ION |
Battery Backup | 6 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 1.6kG Grams |
Dimensions(LXWXH) | 262*173*66 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 40 degree celsius |
Operating Humidity | 90 % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | 3M LONG*5, ALLIGATOR CLIPS*5, EXTERNAL DC ADAPTER, SOFTWARE CD, USER MANUAL |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT III-1000V, CAT IV-600V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 001 |
TTC Report Date | 18/10/17 |
Name Of Lab | KUSAM MECO |
Address Of Lab | MUMBAI |
Interface | SUPPORT USB PORT TO CONNECT PC |