× All the transactions performed on 2.0 is available here. To access Market click "Home".

Digital Multimeter (Meco,matrix or Mastech)(171)

` 2,950.00

  • MRP: `3500.00

Digital Multimeter, 3 - 5/6 DIGITS 6000 COUNTS AUTORANGING DIGITAL MULTIMETER - TRMS , Features Temperature 40C 1000C / -40F 1832FPower Two 1.5 V AA BatteryLow Power IndicationBattery Life 200 hours typicalDimensions 180 x 90 x 52mm approx DC Voltage 600 Mv /6 / 60 / 600 / 1000v AC Voltage 600 MV / 6 / 60 / 600 /750 v DC Current 600 / 6000 A / 60 / 600 mA / 6 / 20 A AC Current 600 / 6000 A / 60 / 600 mA / 6 / 20 A Resistance 600 / 6 / 60 / 600 k / 6 / 60 M Capacitance 9.999 / 99.99 / 999.9 nF / 9.999 / 99.99 / 999.9 F / 9.999 mF Frequency 99.99 Hz 20.00 MHz Sp.Function Diode Test, Audible Continuity, Data Hold Weight 370 gms Including Battery approx Accessories Test Leads Pair, Holster, Battery installed, Instruction Manual K Type Thermocouple upto 260C.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 2
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 6000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 6000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 20
Operating Humidity (RH) 20
Power Requirements 230 V +-10 AC, 50 Hz +- 3 through Adaptor
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 1
Total Voltage Of Battery 9v
Standard Accessories Supplied With The Equipment yes
Dimensions (H X W X L) 100x 150x 60mm mm x mm x
Weight 250 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. ERTL(W)2002 EMI 150
Test Report Date 13.03.2002
Name Of The Lab ERTL(WEST)
Warranty 1 Year

Price Dekho Price Dekho Price List in india