Cat No. 840-210600 Optical DesignDouble Beam with sample and reference cuvette positions Application Focused Beam Geometry Czerny-Turner Monochromator Detector TypeDual Silicon PhotodiodesLampXenon Flash Lamp, 3 year warranty 7 years typical lifetimeNoise0A 0.00015A 1A 0.00025A 2A 0.00080A 260nm, 1nm SBW, RMSData Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nmResolution toluene in Hexane 1.8APhotometric Accuracy 60 mg/L K2Cr2O7 0.010AStray Light 1T at 198nm KCI or to 0.05 T at 220nm Nal, KlPhotometric Accuracy Instrument1A 0.006A 2A 0.010APhotometric Display-0.3 to 4.0APhotometric Range3.5APhotometric Repeatability0.0002AScan Ordinate ModesAbsorbance, Transmittance, Reflectance, Kubelka-Munk, log 1/R, log Abs, AbsFactor, IntensityScan Speed1-6000nm/min, variableSpectral BandwidthVariable 1.0nm 2.0nm Wavelength Accuracy0.5nm Wavelength Range190 to 1100nmWavelength Repeatability0.05nm.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | On request |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | ambient Degree C |
Operating Humidity (RH) | ambient % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | na |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | na |
Test Report No. | na |
Test Report Date | na |
Name Of The Lab | na |
Warranty | 1 Year |