The CNT-90 Frequency Timer/Counter/Analyzer is excellent for measurement, analysis and calibration of frequency, time, or phase. In production test systems, RD, the calibration lab, or in the field the CNT-90 timer/counter/analyzer outperforms many existing counters on the market.The CNT-90 is a high performance Frequency Counter with a fast measurement speed up to 250,000 measurements/sec, with a memory deapth of 750K to internal memory high Resolution of 100 ps single shot time and 12 digits /sec resolution Frequency. The CNT 90 offers ease of use, a multi - mode graphic /numeric display and improved control over measurements , at a very competitive price..
Other Specifications Download Specification | |
---|---|
Frequency Range | 2 mHz to 3 GHz |
No. Of Channels | 2 No. |
Input Connector | BNC & N connector |
Type Of Input Signal | Burst, AM, FM and Noise Signal etc. |
Resolution | 10 or better Digit |
Input Impedance | 1 Mega Ohm |
Trigger Slope | Positive |
Display Type | Backlit (LCD Graphics Screen for Menu Control, Numerical Read Output & Status Information. |
Measurement | Frequency Period, Time, Phase, Volt,Duty Cycle, Pulse, Rise Time |
Indication | Frequency Level Status Indication (Bar Graph, Histogram) |
No. Of Digits | Programmable |
Time Base Type | OCXO |
Gate Time | 20 ns to 1000 s |
Single Shot Time Resolution | 100 Pico Sec |
Calibration | Electronic |
Aging Rate Per Year (AS Declared By The OEM) | 2 PPM |
Temperature Stability At 26 Degree C | 0.02 PPM |
Interface | GPIB & USB |
Operating Temperature | 0 to 40 (Degree C) Degree C |
Storage Temperature | -20 TO +60 (Degree C) Degree C |
Short Warm Up Time | 45 Minutes |
Power Rating | 90 Watt |
Power Supply | 100 -240 Volt |
Operating Humidity (RH) | 0 TO 95 (RH)(%) % |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
Standard Accessories Supplied With The Equipment | Mains Lead, BNC to BNC Lead, Operating Manual. |
Dimensions (H X W X L) | (90 X 210 X 395 )(Mm X Mm X) mm x mm x |
Weight | 2.7 Kg |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)/EL(C)/2013/087 |
Test Report Date | 12/03/2013 |
Name Of The Lab | NATIONAL TEST HOUSE CHENNAI |
Warranty | 1 Year |