solar water heating system 1000 lpd (max power)(max power 1000 lpd)

` 305,000.00

  • MRP: `345000.00

SOLAR WATER HEATING SYSTEM.

  • Availability: 25 In Stock
  • Min. Qty. Per Consignee: 3
  • BIS Approved - Yes
  • If Yes , Mention CM/L No. otherwise put NA - 8775608
  • Model Number of Solar Water Heater System - MAX POWER 1000 LPD
  • Region - Type 1 Cold (Areas where ambient temp. reaches 5 degree C or below)
  • Electrical Heater ( Back up ) Capacity - 9 kw
Other Specifications Download Specification
Confirmity To Standards For Solar Water Heating System -Code For Acceptance IS : 12976:1990 with latest amndmt.
BIS Approved Yes
If Yes , Mention CM/L No. Otherwise Put NA 8775608
Model Number Of Solar Water Heater System MAX POWER 1000 LPD
Solar Water Heating System Compaitabilty With Heat Exchange Solar Water Heating System with Heat Exchanger
Region Type 1 Cold (Areas where ambient temp. reaches 5 degree C or below)
Rated Capacity In Litres Per Day 1000 LPD
Aperture Area Of Collector , Sq. Meteres 2 Sq Meter
Electrical Heater ( Back Up ) Capacity 9 kw
Capacity Of Make Up Tank( SWHS With Heat Exchanger Only ) NA Ltrs
Solar Flat Plate Shall Be BIS Marked And As Per IS :12933/2003 With Amndmt 1 To 3 Yes
Type Of Cover Plate Conforming To IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum
Solar Transmittance For Cover Plate At Normal Incidence 82 %
Material For Collector Box Aluminium
Numbers Of Collectors 8
Minimum Channel Section Thickness For Sides ( For Al Based) MUST BE >=1.4 Mm Otherwise Put 0 For CRCA Material 1.6 mm
Minimum Thickness Of Sheet For Bottom ( For Al Based), MUST BE >=0.45 Mm Otherwise Put 0 For CRCA Material 0.46 mm
Minimum Thickness Of Sheet Used As Support For Glass Retaining ( For Al Based), MUST BE >=1.2 Mm Otherwise Put 0 For CRCA Material 1.2 mm
Thickness Of Sheet For Entire Body ( For Al Based), MUST BE >=1.0 Mm Otherwise Put 0 For CRCA Material 1.6 mm
CRCA Material Thickness, Minimum MUST BE >=0.91 Mm Otherwise Put 0 For Al Material NA mm
Riser And Header Assembly Desigmed For Working Pressure 24.5 K Pa Shall Be Tested For Leakage At A Minimum Hydraulic Pressure Of 490 K Pa Yes
Number Of Absorber Sheets Per Collector 9
Numbers Of Header Tubes 2
Numbers Of Riser Tubes 9
Diameter Of Header Tube 25.4 mm
Diameter Of Riser Tube 12.7 mm
Thickness Of Header Tube 0.71 mm
Thickness Of Riser Tube 0.56 mm
Material Of Riser /Header For Absorber Copper Only
Distanace Between Risers From Center To Center 120 mm
Material Of Sheet For Absorber Copper
Collector Box Insulation Back and sides
Thermal Resistance Of Insulation In Square Degree For Back Face(must Be Greater Than >=0.96) 0.96 W/K m
Thermal Resistance Of Insulation In Square Degree For Side Face(must Be Greater Than >=0.47) 0.47 W/K m
Gasket And Grommets Shall Confirm To IS 12933/2003 With Latest Amndmt. Yes
Material For Hot Water Storage Tank SS304
Name The Material If Choose Others NA
Non Pressure Type Hot Water Storage Tank Yes
Position Of Hot Water Tank Vertical
Thickness Of Sheet Of Hot Water Tank 1.5 mm
Hot Water Tank Insulation Density ( High Density PUF Insulation For 32 Kg/ Meter Cube Or Higher Density 40 mm
Hot Water Welding TIG
Coating Material For Hot Water Tank Polyster Epoxy Plus Balck Epoxy based Paint
Thickness Of Coating 50 micron
Tank Stand Material Mild Steel
Size Of Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 38*38*4 mm3
Type Of Heat Exchanger cage Type
Material For Heat Exchanger Stainless Steel
Thickness Of Tube Of Heat Exchanger , Minimum 22 SWG 22
Heat Transfer Rate For Heat Exchanger , Must Be Greater Than 0.24 Sq Meter Per 100 LPD Capacity 0.24
Numbetrs Of Electrical Heaters ( Back Up Type ) Provided 3
Collector Stand Material Mild Steel
Size Of Collector Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 38*38*4 mm3
System Interconnecting Pipes Material G I Pipes as per IS 1239
If Other Mention The Material For Interconnecting Pipes NA
Size Of Interconnecting Pipes 25.4 mm
Tank Test Pressure 2 bar
System Working Pressure 1 Bar
Inlet And Outlet Valve Yes
Temp Gauge( For Hot Water ) Yes
Gun Metal Strainer ( For Cold Water ) Yes
Water Meter Yes
Gasket For Flanges Synthetic gasket used between Flanges
Electrical Back Up Control Panel Yes
Make Of Control Panel Seimens
If Others , Mention The Make Of Control Panel NA
Weight Of Solar Water Heater System 700 kg
Availability Of Schematic Drawing Yes
Instruction Manual For Installation , Repair And Maintanance Yes
Warranty 1 Years
Availability Of Test Report As Per IS : 6893-6 (1985) Used For Purcahse Specification For Machine Tools , Part 6 Bench /Pillar Type Drill Machine With Latest Amndmt.from Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification Yes
Test Report No. AS BIS
Test Report Date AUG, 2014
Name Of The Lab KAAMRAJ, UNIVERSITY
Address Of The Lab MADURAI