Large character LCD display, easy to read Lower power consumption Indoor/outdoor Temperature, indoor humidity and Clock display simultaneously 2 temperature display modes C/F 2 time display modes 12/24H Max/Min temperature and humidity memory function Temperature range -50C70C -58F158F Temperature accuracy C 1.8F Temperature resolution 0.1C 0.2F Humidity range 1099 RH Humidity accuracy 5 RH Humidity resolution 1 RH Power source 1AAA 1.5V battery Included Material ABS Color WhiteBalck Dimensions 105x97x23mm, 4 3/16 H x 3 7/8 W x 7/8 Thick Weight 150g.
Other Specifications Download Specification | |
---|---|
Type | Benchtop |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | NA Micro Fara |
Capacitance Measurement Accuracy | NA % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Not Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -50 deg to +70deg |
Operating Humidity (RH) | 10% to 99% RH |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | AAA |
Total Voltage Of Battery | 1 |
Standard Accessories Supplied With The Equipment | probe with wire |
Dimensions (H X W X L) | 105x97x23 mm x mm x |
Weight | 150 gram gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 1-35-44/50 |
Test Report Date | 05-07-2017 |
Name Of The Lab | kompex meter india pvt ltd |
Warranty | 1 Year |