INFANT CARE WARMER IS SERVO CONTROL SYSTEM TO MAINTAIN AN OPTIMUM SKIN TEMPERATURE, STANDARD TEMPERATURE DISPLAY WITH MANUAL MODE AND ALARM SATING..
Other Specifications Download Specification | |
---|---|
GMDN Code(s) | CT 1469 |
"Definition:A Bed Or Crib Designed For New Born Babies, For Care Of Neonate As A Body Positioning Device It Is Ususally Opened Rectangular Receptacle And Mounted On A Wheeled Frame Work (trolley). It Is Padded Or Lined With Appropriate Bedding And Used Mostly As The General Purpose Or Standard Baby Bed In Berthing Departments. Source Of Additional Heating Can Be Provided To The New Born. Used By Neonatal ICU/ SNCU, Labour Room, Maternity Ward A Bed Or Crib Designed For New Born Babies. It Is Ususally Opened Rectangular Receptacle And Mounted On A Wheeled Frame Work (trolley). It Is Padded Or Lined With Appropriate Bedding And Used Mostly As The General Purpose Or Standard Baby Bed In Berthing Departments. Source Of Additional Heating Can Be Provided To The New Born. A Bed Or Crib Designed For New Born Babies. It Is Ususally Opened Rectangular Receptacle And Mounted On A Wheeled Frame Work (trolley). It Is Padded Or Lined With Appropriate Bedding And Used Mostly As The General Purpose Or Standard Baby Bed In Berthing Departments. Source Of Additional Heating Can Be Provided To The New Born." | yes |
Dimensions (Height X Width X Length) | 90-100 height, 40-70 width, 70-80 Length cm |
Net Weight | 30 Kg with loading capacity to be 10 Kg kgs |
Mobility, Portability | Yes, on castors |
"Baby Tray With Mattress, Along With Head Up/down Facility, Mattress Density Approx 25Kg/m3 And With Removable, Washable, Waterproof Cover, Mattress Cover Should Be Biocompatible And Easy To Clean. Lower Shelf Which Is Rotatble And Swivel Castors (100mm) - 2 Castors With Brake. Baby Tray Should Be Of Acrylic Material. It Should Not Topple On 10 Deg Inclined Plane. Baby Bed Should Withstand Upto 10kg Weight. It Should Have Provision For Baby Name Identification Tag/label. " | yes |
Care Giver Should Have A Clean View Of The Neonate Inside The Basinet | yes |
Mattress | yes |
Castors | yes |
Operating Condition: Capable Of Operating Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90% In Ideal Circumstances. An Ambient Air Velocity Is Less Than 0.3 M/s. | yes |
User's Care, Cleaning, Disinfection & Sterility Issues | Complete unit to be easily washable and sterilizable using both alcohol and chlorine agents. |
Certificates (premarket, Sanitary, ..)Performance And Safety Standards (specific To The Device Type); Local And/or International | " ISO 13485 and CE Certified. " |
Warranty | 3 years warranty & one year with min. 3 free servicing. |
Recommendations For Maintenance-Washing Periodically | yes |
Others: List Of Important Spare Parts And Accessories With Their Part Number And Costing. Certificate Of Callibration And Inspection To Be Provided | yes |