× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital multimeter mtq70a (metro q)(mtq-70a)

` 4,599.00

  • MRP: `5300.00

The new Auto Ranging 3 Multimeter with USP of Non Rotary selection. It is a light weight instrument with a protective shock proof hostler DCV 400mV/4V/40V/400V/1000V0.54 ACV 400mV/4V/40V/400V/750V0.810 DCA 30mA/300mA/10A1.010 ACA 30mA/300mA/10A1.510 Resistance 400/4K/40K/400K/4M/40M0.84 Capacitance 4nF/40nF/400nF/4uF/40uF/200uF2.520 Frequency 10Hz/100Hz/1KHz/10KHz/100KHz/1MHz/30MHz0.320 Special Function MTQ 70A Low battery indicator Data hold Auto Power Off Shockproof protection10A/600mA fuse protection Unit symbol display Duty cycle measurement 0.199.9 Input impedance10M Sampling rate 3 times/s AC Frequency response 40400Hz Max. display 3999LCD size 7050mm Battery 3 V 1.5 V 2 General Characters MTQ 70A Product color Case, dark gray Holster, yellow Product Net Weight Approx. 320g Product dimension 200x90x45mm Standard Accessories Test.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Not Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range 0-75
Operating Humidity (RH) 65
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
If Battery Operated, Type And No. Of Battery 2
Total Voltage Of Battery 3
Standard Accessories Supplied With The Equipment As per OEM
Dimensions (H X W X L) 200X90X45 mm x mm x
Weight 320 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1 Year