Visualize and characterize devices and components with precision and accuracy using the powerful, industry leading RSA5000B Real Time Spectrum Analyzer. This advanced spectrum analyzer makes high performance and sensitivity measurements for spurious signals much faster than other spectrum analyzers, so you can conduct conventional measurements and troubleshoot quickly, accurately and successfully.
Other Specifications Download Specification | |
---|---|
Frequency Range | 20Hz - 6 GHz |
Display Type | Touch Panel 10.4 Inches |
Capture/Demodulation Bandwidth (Max.) | 40 MHz |
I/Q Memory Depth (256 MB) | Yes |
Trigger | Free Run, Power Trigger, External |
Traces Types | Normal (RMS), Average, Max. Hold, Min. Hold |
Sample Rate | 100 Ms/s |
Ref. Frequency Aging (1 X 10 ^ -7) | 0.75 X 10^-7 |
Measurement Range (DANL To Max. Safe Input Level) | -150 dBm to +30 dBm dBm/Hz - dBm |
Max. Safe Input Level (Should Be Less Than Or Equal To +30 DBm ) | Yes |
Displayed Average Noise Level ( 10 MHz To 3/6/13/26.5 GHz, DANL Should Be Less Than Or Equal To -130 DBm/Hz ) | Yes |
Modulation Analysis | AM, FM, PM, BPSK, QPSK, Pi/4 DQPSK, 8PSK, 16SQAM, 32QAM, 64QAM, 128QAM, 256QAM, GMSK,GFSK |
"Multi Domain Analysis With Stand Alone Software" | Time, Frequency, Modulation, Spectrogram |
Automatic Measurement (Time Mode) | IQ vs Time, Power vs Time, Frequency vs Time, CCDF, crest factor, Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle Pulse-Pulse, Phase, Channel Power, Occupied BW, Frequency Deviation |
Interface | USB, LAN/GPIB |
Operating Temperature | 5 to 40 degree C and 80 % RH at 40 degree C |
Power Requirements (230 +/- 10% VAC, 50 Hz) | Yes |
Rack Mount Kit For Signal Analyzer | Yes |
Availability Of The Test Report From Central Govt./ NABL/ ILAC Accredited Lab As Per Doc Correction Slip No. 38 Dtd 18/1/12 To Be Read In Conjunction With P&C Circular No. 71 Dtd 29/10/14 For Each Model Of Signal Analyzer. | Yes |
TTC No. & Date | Yes |
Name Of The Lab | Yes |
Address Of The Lab | Yes |
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests. | Yes |
Dry Heat Test: For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. | Yes |
Cold Test: For 4 Hrs At A Temp. Of (-)10 Degree C In Accordance With IS: 9000/part-2/section-4/1977(reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. | Yes |
Damp Heat Test: For 2 Cycles Of 24 Hrs (12 + 12h) Each At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. | Yes |
The Scope Of Supply Shall Include One Set Of Operation And Maintenance Manual For Each Equipment. | Yes |