× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke 437 series ii 400hz power quality and energy analyzer (fluke is world leader in the manufacture distribution and service of electronic test tools)(fluke 437-ii)

` 1,065,000.00

  • MRP: `1190000.00

The Fluke 437 Series II 400Hz Power Quality and Energy Analyzer is designed specifically for the defense and avionics industries. Capable of measuring up to 400 Hz, the 437 II is a must-have for those working in submarines, aircrafts, and other transport applications.400 Hz measurement capture power quality measurements for avionic and military power systems.-PowerWave data capture capture fast RMS values to see every waveform so you can determine how the voltage, current and frequency values are interacting.--Power inverter efficiency measure both ac power and dc power, in and out, to monitor the efficiency of inverters.---Energy monetization calculate the fiscal cost of energy waste due to poor power quality.----Energy assessment quantify the before and after installation improvements in energy consumption to justify energy saving devices.----Frontline troubleshooting quickly diagnose problems on-screen to get your operation back online.----Predictive maintenance detect and prevent..

  • Availability: 0 In Stock
  • Min. Qty. Per Consignee: 0
  • Display type - LCD Backlit
  • Display Mode - 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
  • Number of Current Channels - 4 Nos. Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 0.1 Volts Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type LCD Backlit
Display Mode 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Number Of Current Channels 4 Nos. Nos.
Number Of Voltage Channels 5 Nos Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 1 V to 1000 V Volts Volts
Measurable Voltage Accuracy ± 0.1 %
Measurable Voltage Resolution 0.1 Volts Volts
Facility To Measure RMS Current Available
Measurable Current Range 0.5 A to 6000 A Ampere Ampere
Measurable Current Accuracy ± 0.5 % ± 5 counts
Measurable Current Resolution 0.5 A to 600 A -- 0.1 A & 5A to 6000A --- 1A Ampere Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 6000 MW KW KW
Power Accuracy ± 1 % ± 10 counts
Power Resolution 0.1 W to 1MW Watt Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 42.500 Hz to 69.000 & 340.0 Hz to 460.0 Hz Hz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion ± 2.5 %
Resolution In Measurement Of Total Harmonics Distortion 0.1%
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available 1 to 50 Grouping
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor ± 0.1 %
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor NA
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor ± 0.1 %
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 1.0 > 2.8
Measurable Crest Factor Accuracy ± 5 %
Measurable Crest Factor Resolution 0.01
Screen Memory yes
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory 8GB SD Card memory MB MB
Type Of Battery Used Lithium-Ion
Battery Backup Up to 8 hours Hours Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 2KG Grams Grams
Dimensions(LXWXH) 265 x 190 x 70 mm cmXcmXcm cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery degree celsius degree celsius
Operating Humidity +10 °C ~ +30 °C: 95 % RH non-condensing, +30 °C ~ +40 °C: 75 % RH non-condensing, +40 °C ~ +50 °C: 45 % RH non-condensing % %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Provided
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT-III 1000V, CAT-1V 600V
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. 39553208
TTC Report Date 26/07/2017
Name Of Lab Fluke Corporation (Fluke Corporation ISO-9001 Certified Lab)
Address Of Lab Fluke Corporation USA, further in India Recalibration can be done at FLUKE TECHNOLOGIES PVT. LTD. Address: #1074-A, 8th Cross, 11th Main HAL 2nd Stage, Indiranagar (Behind ESI Hospital) Bangalore - 560 038
Interface USB

Price Dekho Price Dekho Price List in india