BHARTI-SENCO IRON CUM ARSENIC REMOVAL HAND PUMP UNIT WITH INBUILT AUTO BACKWASH SYSTEM FOR IRON UNIT.
Other Specifications Download Specification | |
---|---|
Iron Removal Unit | With |
Prefilter Provided With Flushing Valve In The Iron Removal Unit | YES |
Iron Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Discharge Capacity Of The Iron Removal Equipment | 15 LPM LPH |
Material Of Body Of Iron Removal Equipment | Mild Steel |
Diameter Of Vessel Of Iron Removal Equipment | Top ID - 510 +/- 30, OD - 600 +/- 30 , Bottom ID - 445 +/- 30, OD - 598 +/- 30 mm |
Height Of Vessel Of Iron Removal Equipment | Top- 483 +/- 30, Bottom 445 +/- 30 mm |
Number Of Iron Removal Vessel | 1 Nos |
Minimum Thickness Of Vessel Of Iron Removal Equipment | 3 +/- 0.5 mm |
Material Of Strainer Plate Of Iron Removal Equipment | Mil Steel |
Diameter Of Strainer Plate Of Iron Removal Equipment | 443 +/- 30 mm |
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment | 3 +/- 0.5 mm |
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment | 11 Nos |
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment | 1 Nos |
Material Of Strainer In Strainer Plate Of Iron Removal Equipment | Poly Propylene |
Quantity Of Iron Removal Media In Iron Removal Vessel | 21 +/- 3 Kg |
Quantity Of Filter Media In Iron Removal Media | NA Kg |
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel | NA |
Back Wash Valve In Iron Removal Vessel | Inbuilt auto back wash system by manually operated valve ( pumping is not required for back wash) |
The Accumulated Ferric Is Removed From The Media While Back Washing | YES |
Maximum Iron Content Of Inlet Water | 20 ppm |
Maximum Iron Content Of Outlet Water | 0.3 ppm |
Process By Which Iron Is Removed From Water By Iron Removal Media | 1. Iron removal media works through oxidation process. 2. Ferrous is oxidized to ferric state and gets filtered in the media which acts as a filter bed also. |
Life Of Iron Removal Media | 4 Years |
Cost Of Refilling Of Iron Removal Media | 350.00 per kg Rupees |
Life Of Iron Removal Unit | 10 Years |
Protective Coating Of Iron Removal Vessel | Hot Dip Galvanized |
Inlet Pipe Size Of Iron Removal Unit | 40 (IS : 1239) mm |
Space Required For Installation Of Iron Removal Unit | One Square Metres |
Number Of Valves In Iron Removal Unit | 02 Nos |
Materal Of Valve Of Iron Removal Unit | Brass body, SS Ball |
Diameter Of The Valve In Iron Removal Unit | 40 mm |
Pressure Gauge In Iron Removal Unit | NO |
Pressure Release Valve In Iron Removal Unit | NO |
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit | NA Kg/square cm |
Weight Of Iron Removal Unit | 120 +/- 10 Kg |
Warranty Period Of Iron Removal Unit | 4 Years |
Arsenic Removal Unit | With |
Discharge Capacity Of The Arsenic Removal Unit | 12 LPM LPH |
Arsenic Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Material Of Arsenic Removal Vessel | Mild Steel |
Diameter Of Arsenic Removal Vessel | ID : 445 +/- 30, OD : 530 +/- 30 mm |
Height Of Arsenic Removal Vessel | 475 +/- 30 mm |
Minimum Thickness Of Arsenic Removal Vessel | 3 +/- 0.5 mm |
Number Of Arsenic Removal Vessel | 1 Nos |
Material Of Strainer Plate Of Arsenic Removal Vessel | Mild Steel |
Diameter Of Strainer Plate Of Arsenic Removal Vessel | 445 +/- 30 mm |
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel | 3 +/- 0.5 mm |
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate | 11 Nos |
Material Of Strainer In Arsenic Removal Strainer Plate | Poly Propylene |
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel | 25 +/- 3 Kg |
Media Used For Removal Of Arsenic From Water | Iron (III) Hydroxide Oxide |
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel | NA |
Maximum Arsenic Content Of Inlet Water | 5 ppm |
Maximum Arsenic Content Of Outlet Water | 0.01 ppm |
Life Of Arsenic Removal Media | 3 Years |
Cost Of Refilling Of Arsenic Removal Media | 497.00 per kg Rupees |
Life Of Arsenic Removal Unit | 10 Years |
Protective Coating Of Arsenic Removal Vessel | Hot Dip Galvanized |
Inlet Pipe Size Of Arsenic Removal Unit | 40 (IS : 1239) mm |
Space Required For Installation Of Arsenic Removal Unit | One Square Metres |
Number Of Valves In Arsenic Removal Unit | NA Nos |
Materal Of Valve In Arsenic Removal Unit | NA |
Diameter Of The Valve Of Arsenic Removal Unit | NA mm |
Pressure Gauge In Arsenic Removal Unit | NO |
Pressure Release Valve In Arsenic Removal Unit | NO |
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit | NA Kg/square cm |
Weight Of Arsenic Removal Unit | 90 +/- 10 Kg |
Warranty Period Of Arsenic Removal Unit | 4 Years |
Iron Removal Media Conform To International Standard | National Science Foundation, USA |
Arsenic Removal Media Conform To International Standard | DIN EN 15029 |
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate | YES |
Field Testing Kit For Testing Iron & Arsenic Is Provided | YES |