MetroQ MTQ-1090 Analog Multimeter Features- Innovated accurate , Shock Proof handheld instrument with robust protective holster alongside and back Tilt Device with hook up Design. It can offer accurate , reliable , True-RMS measurements with high Quality Band Movement. Double sided Glass Epoxy PCB Unique -Designed Circuit as well as Mirrored Aluminium dial Plates etc. It has Full overloaded mis-used protrection via two Fuses , oxide Varactors and Diodes. Power On Light Indicator with Auto Power Off. Heavy ABS Housing Compact Protective Holster Along Side. High Input Impedance 10 M/DCV/ACV. True RMS Reading for ACV/ACV testing. High quality Band Movement Built in. Resistance Test Range - X1 , X10 , X100 , X1K , X10K , X100K , X1M. Special Functions - Dry Battery Test. Continuity Buzzer. Decibels Test. Diode Test. Transistor hFE Test. AC Voltage Volts - 0.05-1000 V, AC Voltage Accuracy - Greater Then 3 of full scale..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | NA Micro Fara |
Capacitance Measurement Accuracy | NA % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Not Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0-45 |
Operating Humidity (RH) | 95 |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
If Battery Operated, Type And No. Of Battery | 2 |
Total Voltage Of Battery | 3V |
Standard Accessories Supplied With The Equipment | As per OEM |
Dimensions (H X W X L) | 160x105x40 mm x mm x |
Weight | 450 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 25662 |
Test Report Date | 11-08-2017 |
Name Of The Lab | Metro Q |
Warranty | 1 Year |