The Fluke 434 II Energy Analyzer is the ideal tool for energy logging. Utilizing the new Energy Loss Calculator function, the 434 II measures the fiscal cost of energy wasted due to poor power quality. This energy monetization capability allows you to identify the most energy-wasteful areas of your facility so you can determine potential energy saving solutions. Add basic power quality measurements to the package and you are got yourself one powerful troubleshooting tool..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | LCD Resolution: 320 x 240 pixels |
Number Of Current Channels | 5 Nos. |
Number Of Voltage Channels | 4 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1 -1000 Volts |
Measurable Voltage Accuracy | 0.5% |
Measurable Voltage Resolution | 0.1 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 0.5 - 6000 Ampere |
Measurable Current Accuracy | 0.5% |
Measurable Current Resolution | 0.1 Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 6000 KW |
Power Accuracy | 1% |
Power Resolution | 0.1 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42.5 to 69 Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | 0.1% |
Resolution In Measurement Of Total Harmonics Distortion | 0.1% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 50 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | 0.1% |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | 0.1% |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | 0.1% |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1 - 10 |
Measurable Crest Factor Accuracy | 5% |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | 100 |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 8 GB MB |
Type Of Battery Used | Li-ion |
Battery Backup | 8 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 2000 Grams |
Dimensions(LXWXH) | 26.5 x 19 x 7 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0 °C ... +40 °C; +40 °C ... +50 °C excl. battery degree celsius |
Operating Humidity | +10 °C ... +30 °C: 95 % RH non-condensing; +30 °C ... +40 °C: 75 % RH non-condensing; +40 °C ... +50 °C: 45 % RH non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | 5 voltage probes with Alligator clips & 4 current clamps |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | 600V CAT IV 1000V CAT III |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 3945642 |
TTC Report Date | 15 oct 2017 |
Name Of Lab | Fluke Corporation |
Address Of Lab | USA |
Interface | USB & Bluethooth |