A capacitor tester meant for use by industrial workers, the MetroQ Digital Capacitance Meter MTQ 1500 comes with a number of accessories such as test leads, battery, manual and gift box. It comes with an OL LCD display and has an accuracy of 0.8. The device comes with a power supply of 1.5 V and a frequency of 8 Hz. The Handheld Instrument can Detect as well as measure Capacitance, Resistance and Diode Automatically. Also the Instrument self Discharge the Charge Capacitor before Measurement. It has also Data Hold Capacity..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 200 Micro Fara |
Capacitance Measurement Accuracy | NA % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | 2 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0-45 |
Operating Humidity (RH) | 95 |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 1.5V*2 (AAA) |
Total Voltage Of Battery | 3 V (1.5 V × 2) AA alkaline batteries |
Standard Accessories Supplied With The Equipment | Test Lead, Battery Manual, Gift Box |
Dimensions (H X W X L) | 185 x 91x 49 mm x mm x |
Weight | 408 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 25662 |
Test Report Date | 11-08-2017 |
Name Of The Lab | Metro Q |
Warranty | 1 Year |