× All the transactions performed on 2.0 is available here. To access Market click "Home".

Electromagnetic Field Test Meter EMF-523 (HTC)(EMF-523)

` 14,750.00

  • MRP: `18000.00

RF Three Axis Field Strength Meter 50Mhz to 3.5Ghz. Records Maximum AVG. Memory Recall Adjustable. Adjustable Threshold ON/OFF. Measuring Units mV/m, V/m, A/m, mA/m, W/m, mW/m, W/cm. Range 38mV - 20V/m Resolution 0.1mV - 0.01 W/m Frequency 50Mhz - 3.5 Ghz Sample Rate 2.5 times/S Power 9V Battery Standard Accessories Hard Carrying case, Instruction Manual Dimensions 60 x 60 x 195 mm Model No EMF-523.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Not Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range 0-50
Operating Humidity (RH) 95
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
If Battery Operated, Type And No. Of Battery 9 V (6F22) Battery
Total Voltage Of Battery 9
Standard Accessories Supplied With The Equipment NA
Dimensions (H X W X L) 138x69x31 mm x mm x
Weight 170 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1 Year

Price Dekho Price Dekho Price List in india