Spectrometer designed for students as per IS 6471-1971Amdt no 1, Reaffirmed 1998.. The main structure is to be of cast iron base with leveling screws. Shall have brass protected circle read by two opposite verniers. 10x Ramsden eye piece eye piece holder with fine cross wire to be provided. The objective to be of 25 mm aperture 150 mm min focal length. The lenses of collimator and telescope are to be achromatic. Rack pinion movements are to be provided to both telescope 7 collimeter. Supplied in a well polished wooden case. Protected circle...
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | N/A Degree C |
Gperating Humidity (RH) | N/A % |
PC Interface | USB |
Dimensions | N/A mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | N/A |
Test Report Date | N/A |
Name Of The Lab | N/A |
Warranty | 1 Year |