DIGITAL STORAGE OSCILLOSCOPE 70MHz 4 CHANNEL, 2GSa/s, 140Mpts record Length, 140000 wmf/s waveform capture rate,.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground |
Time Base Range | 1 ns/div to 50 s/div |
Trigger Types | Edge, Slope, Pulse Width, Video, Window, Interval, Dropout, Runt, Pattern, Serial |
Measurements | 37 Types of Automatic Measurements of Time, Voltage, Delay. Math Function - Add, Subtract, Multiply, Divide, FFT, Integration, Differentiation, Square Root, FFT |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Auto, Normal, Peak Detect, Enhance Resolution |
Display Type | Colour |
Display Size | 20.32 CM |
I/O Interface | USB Host, USB device, LAN, Pass / Fail, Trigger out |
Standard Accessories To Be Supplied | 4 no. Passive Probe, Power Cord, USB Cable, CD (including User Manual an EasyScopeX Software), Quick Start, Calibration Certificate |
Operating Temperature Range | 10 deg C to 40 deg C Degree C |
Operating Humidity (RH) | 85% RH % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 201709273 |
Test Report Date | September 16, 2017 |
Name Of The Lab | Siglent |
Warranty | 3 Year |
Real Time Bandwidth | 70 MHz |
Record Length Per Analog Channel Simultaneously | 70 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/sec |
Waveform Update Rate | 140000 Waveforms/ |
Time Base Accuracy | 25 PPM |