Resettable Circuit Breaker Easy Recovery From Overloads No Need To Replace A Fuse. Safety-Agency Approved Ensures The Product Has Been Tested And Approved To Work Safely With The Connected Service Provider Equipment And Within The Specified Environment. Input Power Factor Correction Minimizes Installation Costs By Enabling The Use Of Smaller Generators And Cabling. Cold-Start Capable Provides Temporary Battery Power When The Utility Power Is Out. Power Conditioning Protects Connected Loads From Surges, Spikes, Lightning, And Other Power Disturbances. Frequency And Voltage Regulation Gives Higher Application Availability By Correcting Poor Frequency And Voltage Conditions Without Using The Battery. Generator Compatible Ensures Clean, Uninterrupted Power To Protected Equipment When Generator Power Is Used...
Other Specifications Download Specification | |
---|---|
Rating In KVA | 6 KVA |
Technology | IGBT-PWM with inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 120 Minutes |
Minimum VAH | 12480 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 1 % |
Overall Efficiency | 90 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | R-83000450 |
Type Test Certificate Date | 10 July 2017 |
Name Of Lab | BIS |
Address Of Lab | Manak Bhavan, 9, Bahadur Shah Zafar Marg New Delhi-110002 |
Supply & Commissioning | YES |
Warranty | 2 Years |