× All the transactions performed on 2.0 is available here. To access Market click "Home".

Battery Charger CVCC Type-SMPS 3 STATION (avr power solutions)(AVRLBC3S12A)

` 21,262.50

  • MRP: `24050.00

BATTERY CHARGER CONSTANT CURRENT TYPE, 3 STATION, Voltage 12 Volts, Current Per Station 12 Amps, No. of Station 3, Technology-SMPS, With Experience of More Than 8 Years in the Manufacturing of Battery Chargers, We were The Larges Selling Firm on the DGSND Rate Contract for This Item, Our Customer includes BSF CRPF, ITBP, SSB, CISF, NSG, State Police Forces And Indian Railways ETC..

  • Availability: 108 In Stock
  • Min. Qty. Per Consignee: 1
  • Compatibility with battery type (User Selectable) - Lead acid & Tubular &VRLA-SMF
  • Battery/battery bank Voltage - 12 Volts
  • Capacity of the battery to be charged(User Selectable) - 7 To 150 AH AH
  • Number Of Independent charging Stations - 3 Nos. Nos.
  • Efficiency - More Than 75% For SMPS At 230V %
Other Specifications Download Specification
Charger Technology SMPS Based
Compatibility With Battery Type (User Selectable) Lead acid & Tubular &VRLA-SMF
Battery/battery Bank Voltage 12 Volts
Capacity Of The Battery To Be Charged(User Selectable) 7 To 150 AH AH
Maximum Charger Output Current 12 Amp Amp
Number Of Independent Charging Stations 3 Nos. Nos.
Charging Cut-off Voltage Per 12V Battery 14.5V +/- 0.2V Volts
Input Voltage Range 160 To 270 VAC VAC
Efficiency More Than 75% For SMPS At 230V %
Ripple (Peak To Peak At Full Load) Less Than 100 MV millivolts
Reverse Polarity Protection Yes
Short Circuit Protection Yes
Over Current Protection Yes
AC Surge Protection with MOV
Soft Start And Soft Stop Feature Without Inrush Current Yes
Over Voltage Cutoff Protection Yes
Facility For Charging Deep Discharged Battery Through Pulse Charging. Yes
Cut-in Voltage For Charging A Discharged Battery 10.5 V Volts
Cut-off Voltage For Charging A Discharged Battery 14.5V +/-0.2V Volts
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V Yes
Digital Display Of Output Voltage And Current Yes
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity Yes
Cabinet Material CRCA Sheet
Cabinet Thickness Min. 1.2 mm mm
Length Of Charging Cable For Each Station. Min. 1.5 Meter metre
Size Of Charging Cable For Each Station. 6 Sq. MM sq. mm
Minimum Operating Temperature 0 Degree Celsius Degree Celsius
Maximum Operating Temperature 60 Degree Celsius Degree Celsius
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. Yes
Type Test Report No. ETDC(MH)/T&M/079
TTC Report Date 29-09-2014
Name Of Lab STQC-ETDC (Govt. Of India Lab)
Address Of Lab B-108, Pase-8, Industrial Area, SAS Nagar, MOhali, Punjab

Price Dekho Price Dekho Price List in india